Comparison of Cool Tip Versus 8‐mm Tip Catheter in Achieving Electrical Isolation of Pulmonary Veins for Long‐Term Control of Atrial Fibrillation: A Prospective Randomized Pilot Study
- 18 July 2006
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 17 (10) , 1074-1079
- https://doi.org/10.1111/j.1540-8167.2006.00558.x
Abstract
To compare safety and efficacy of 8-mm versus cooled tip catheter in achieving electrical isolation (EI) of pulmonary veins (PV) for long-term control of atrial fibrillation (AF). There is paucity of studies comparing safety/efficacy of 8-mm and cooled tip catheters in patients undergoing AF ablation. This was a randomized and patient-blinded study. Subjects were followed by clinic visits (at 6 weeks and 6 months) and transtelephonic monitoring (3-week duration) done around each visit. Primary endpoints were: (1) long-term AF control (complete freedom and/or >90% reduction in AF burden on or off antiarrhythmic drugs at 6 months after a single ablation), and (2) occurrence of serious adverse events (cardiac tamponade, stroke, LA-esophageal fistula, and/or death). Eighty-two patients (age 56 +/- 9 years, 60 males, paroxysmal AF = 59) were randomized (42 patients to 8-mm tip and 40 patients to cooled tip). EI of PVs was achieved in shorter time by the 8-mm tip as compared with cooled tip catheter (40 +/- 23 minutes vs 50 +/- 30 minutes; P < 0.05) but long-term AF control was not different between the two (32 patients [78%] vs 28 patients [70%], respectively; P = NS). One serious adverse event occurred in each group (LA-esophageal fistula and stroke, respectively) and no significant PV stenosis was observed in either. EI of PVs using either 8-mm or cooled tip catheter results in long-term AF control in the majority after a single ablation procedure, with comparable efficacy and safety.Keywords
This publication has 22 references indexed in Scilit:
- Temporary Esophageal Stenting Allows Healing of Esophageal Perforations Following Atrial Fibrillation Ablation ProceduresJournal of Cardiovascular Electrophysiology, 2006
- Electrophysiological Findings During Ablation of Persistent Atrial Fibrillation With Electroanatomic Mapping and Double Lasso Catheter TechniqueCirculation, 2005
- Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial FibrillationCirculation, 2005
- Presence of Left-to-Right Atrial Frequency Gradient in Paroxysmal but Not Persistent Atrial Fibrillation in HumansCirculation, 2004
- Efficacy of Repeat Pulmonary Vein Isolation Procedures in Patients with Recurrent Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2004
- Left Atrial–Esophageal Fistula Following Radiofrequency Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2004
- Atrio-Esophageal Fistula as a Complication of Percutaneous Transcatheter Ablation of Atrial FibrillationCirculation, 2004
- Electroanatomic Mapping of Human Heart:Journal of Cardiovascular Electrophysiology, 2003
- Phased-Array Intracardiac Echocardiography Monitoring During Pulmonary Vein Isolation in Patients With Atrial FibrillationCirculation, 2003
- Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial FibrillationCirculation, 2002