Monitoring of Functional Residual Capacity by an Oxygen Washin/Washout; Technical Description and Evaluation
- 11 July 2006
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 20 (4) , 251-260
- https://doi.org/10.1007/s10877-006-9029-9
Abstract
Objective. It was the goal of this study to develop and test an automated method for measuring functional residual capacity (FRC) by an oxygen washin/washout in intensive care settings. Such a method is required to work with conventional ventilator breathing systems and to use only medical grade sensors. Methods. The oxygen setting on a standard intensive care ventilator is changed by at least 10percnt;. Ventilatory pressure and flow are measured by the built-in sensors of the intensive care ventilator. Oxygen concentration is measured by a diverting medical oxygen analyzer. In order to overcome the known problem that synchrony between flow and concentration measurement is corrupted by the change of gas viscosity and by the cyclic change of airway pressure, a physical/mathematical model of the pneumatic circuit of the analyzer was developed. With this model, the change of sample flow is calculated continuously. Thus, synchrony between flow and gas concentration measurement is restored. This allows the determination of volumetric gas fluxes as needed for the FRC measurement. The setup was tested in the laboratory with a lung simulator. Simulated lung compliance, breathing frequency and tidal volume were varied. Results. The mean difference between measured and simulated FRC (range 1.7 to 5 L) was less than 1percnt; at tidal volumes greater than 400 mL. This difference ranged from −5percnt; to 8percnt;, depending on simulated lung compliance and ventilator setting. The variability of consecutive measurements was about 2.5percnt;. Conclusions. A method has been developed for reliable measurement of the FRC with an oxygen washin/washout technique. This method is sufficiently easy to use to suit for application in intensive care units. It does not require any action by the operator except a manual change of inspired oxygen concentration. Accuracy and sensitivity of the method have been proven sufficient to meet clinical and scientific requirements. Future clinical studies will reveal the applicability of the chosen procedure under clinical conditions.Keywords
This publication has 12 references indexed in Scilit:
- Measurement of functional residual capacity by nitrogen washout during partial ventilatory supportIntensive Care Medicine, 2003
- Automated evaluation of functional residual capacity by oxygen washout.Journal of Clinical Monitoring and Computing, 2002
- A method of reconstruction of clinical gas-analyzer signals corrupted by positive-pressure ventilationJournal of Applied Physiology, 2001
- A simple method to estimate functional residual capacity in mechanically ventilated patientsIntensive Care Medicine, 1993
- The recording of FRC — is it of importance and can it be made simple?Intensive Care Medicine, 1993
- Measurement of Lung Volume by Sulfur Hexafluoride Washout during Spontaneous and Controlled VentilationAnesthesiology, 1987
- Accurate measurement of N2 volumes during N2 washout requires dynamic adjustment of delay timeJournal of Applied Physiology, 1985
- Measurement of Functional Residual Capacity by Sulfur Hexafluoride WashoutAnesthesiology, 1985
- Measurement of functional residual capacity during mechanical ventilation. Comparison of a computerized open nitrogen washout method with a closed helium dilution methodIntensive Care Medicine, 1983
- Oxygen wash-in method for monitoring functional residual capacityCritical Care Medicine, 1982