Elective Endovascular Stent-Graft Repair of Atherosclerotic Thoracic Aortic Aneurysms:Clinical Results and Midterm Follow-Up
- 1 March 2003
- journal article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 180 (3) , 709-715
- https://doi.org/10.2214/ajr.180.3.1800709
Abstract
OBJECTIVE. The purpose of this study was to evaluate the clinical and midterm results after endovascular treatment of atherosclerotic thoracic aortic aneurysms. MATERIALS AND METHODS. Twenty-eight consecutive patients who were 53-82 years old (mean age, 71.6 years) were treated with a commercially available endoprosthesis. Subclavian transposition or bypass surgery was performed before the procedure in eight patients. Size dynamics of the aneurysms were analyzed on the basis of diameter and thrombus volume measurements obtained on three-dimensional CT reconstructions before hospital discharge (n = 22) and at the 1-year (n = 22), 2-year (n = 12), and 3-year (n = 5) follow-ups. RESULTS. The technical success rate was 100%. There was no 30-day mortality. None of the patients had symptoms due to spinal cord ischemia. The survival rate at 1, 2, and 3 years was 96.1%, 90.9%, and 80.2%, respectively. During the perioperative period, patients presented with leukocytosis (37%), fever (36%), elevated C-reactive protein value (92%), pleural effusion (50%), and periaortic atelectasis (41%). Three early type I endoleaks sealed spontaneously. Three early type II endoleaks persisted over time, and one late type II endoleak was detected. In patients with type II endoleaks, thrombus volume of the aneurysms was constant (n = 2) or increased (n = 2). In patients without endoleaks, mean thrombus volume decreased (-53.2 ± 56.8 mL, -40%) significantly (p = 0.001) during the first year. There was no significant interval decrease between the 1- and 2-year follow-ups (mean, -2.4 mL, p = 0.92) and between the 2- and 3-year follow-ups (mean, -0.4 mL, p = 0.68). CONCLUSION. Endovascular treatment of atherosclerotic thoracic aortic aneurysms may result in a substantial reduction of the aneurysm sac in patients without endoleaks.Keywords
This publication has 33 references indexed in Scilit:
- Thoracic Aortic Stent Grafts – Early Experience from Two Centresusing Commercially Available DevicesEuropean Journal of Vascular and Endovascular Surgery, 2001
- Maximal Aneurysm Diameter Follow-up is Inadequate after Endovascular Abdominal Aortic Aneurysm RepairEuropean Journal of Vascular and Endovascular Surgery, 2000
- The abdominal aortic aneurysm sac after endoluminal exclusion: A medium-term morphologic follow-up based on volumetric technologyJournal of Vascular Surgery, 2000
- Thoracic aortic aneurysm repair with an endovascular stent graft: the “first generation”The Annals of Thoracic Surgery, 1999
- The “first generation” of endovascular stent-grafts for patients with aneurysms of the descending thoracic aortaThe Journal of Thoracic and Cardiovascular Surgery, 1998
- Endoluminal Stent–Grafts for Infrarenal Abdominal Aortic AneurysmsNew England Journal of Medicine, 1997
- Expansion Rate of Thoracic Aortic Aneurysms and Influencing FactorsChest, 1992
- Ruptured Aneurysm of the Descending Thoracic and Thoracoabdominal Aorta Analysis According to Size and TreatmentAnnals of Surgery, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Surgical Treatment of Aneurysms of the Descending Thoracic Aorta: An Analysis of 85 PatientsThe Annals of Thoracic Surgery, 1983