Usefulness of a New Radiofrequency Thermal Balloon Catheter for Pulmonary Vein Isolation:
- 6 June 2003
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 14 (6) , 609-615
- https://doi.org/10.1046/j.1540-8167.2003.02577.x
Abstract
Introduction: A rapidly firing or triggered ectopic focus located within a pulmonary vein (PV) or close to the PV ostium could induce atrial fibrillation (AF). The aim of this study was to evaluate the efficacy and safety of a radiofrequency thermal balloon catheter for isolation of the PV from the left atrium (LA). Methods and Results: Twenty patients with drug‐resistant paroxysmal AF were treated by isolating the superior PVs using an RF thermal balloon catheter. Using a transseptal approach, the balloon, which had an inflated diameter 5 to 10 mm larger than that of the PV ostium, was wedged at the LA‐PV junction. It was heated by a very‐high‐frequency current (13.56 MHZ) applied to the coil electrode inside the balloon for 2 to 3 minutes, and the procedure was repeated up to four times. The balloon center temperature was maintained at 60° to 75°C by regulating generator output. Successful PV isolation was achieved in 19 of the 20 left superior PVs and in all 20 of the right superior PVs and was associated with a decrease in amplitude of the ostial potentials. Total procedure time was 1.8 ± 0.5 hours, which included 22 ± 7 minutes of fluoroscopy time. After a follow‐up period of 8.1 ± 0.8 months, 17 patients were free from AF, with 10 not taking any antiarrhythmic drugs and 7 taking the same antiarrhythmic agent as before ablation. Electron beam computed tomography revealed no complications, such as PV stenosis at ablation sites. Conclusion: The PV and its ostial region can be safely and quickly isolated from the LA by circumferential ablation around the PV ostia using a radiofrequency thermal balloon catheter for treatment of AF. (J Cardiovasc Electrophysiol, Vol. 14, pp. 609‐615, June 2003)Keywords
This publication has 18 references indexed in Scilit:
- Circumferential Radiofrequency Ablation of Pulmonary Vein OstiaCirculation, 2000
- Electrophysiological Breakthroughs From the Left Atrium to the Pulmonary VeinsCirculation, 2000
- Initiation of Atrial Fibrillation by Ectopic Beats Originating From the Superior Vena CavaCirculation, 2000
- Initiation of Atrial Fibrillation by Ectopic Beats Originating From the Pulmonary VeinsCirculation, 1999
- Electrosurgical Treatment of Atrial Fibrillation With a New Intraoperative Radiofrequency Ablation CatheterThe Thoracic and Cardiovascular Surgeon, 1999
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsNew England Journal of Medicine, 1998
- Initial clinical experiences with rescue unipolar radiofrequency thermal balloon angioplasty after abrupt or threatened vessel closure complicating elective conventional balloon coronary angioplastyJournal of the American College of Cardiology, 1994
- Radiofrequency thermal balloon coronary angioplasty: A new device for successful percutaneous transluminal coronary angioplastyJournal of the American College of Cardiology, 1994
- Electrical activity of the pulmonary vein and its interaction with the right atrium in the guinea‐pig.The Journal of Physiology, 1981
- The Junction Between the Left Atrium and the Pulmonary VeinsCirculation, 1966