Dose enhancement by a thin foil of high‐Zmaterial: A Monte Carlo study
- 12 July 1999
- journal article
- Published by Wiley in Medical Physics
- Vol. 26 (7) , 1245-1251
- https://doi.org/10.1118/1.598619
Abstract
The purpose of this work is to study the dose enhancement by a thin foil (thickness of 0.2–4 mm) of high‐Zmaterial in a water phantom, irradiated by high‐energy photon beams. EGS4 Monte Carlo technique was used. Perturbations on the beam spectra due to the presence of the foils, and dose enhancement dependence of photon‐beam quality, beam incident angle, atomic number (Z), the thickness and size of the foil, and the depth of the foil situated in the phantom were studied. Analysis of photon and secondary‐electron spectra indicates that the dose enhancement near an inhomogeneity interface is primarily due to secondary electrons. A calculation for 1‐mm‐thick planar lead foil in a water phantom shows that the dose enhancements at 0.25, 1, 2 and 3 mm away from the foil in the backward region were 58%, 37%, 24% and 17%, respectively, for a 15 MV beam. Calculations for a variety of planar foils and photon beams show that dose enhancement: (a) increases withZ; (b) decreases with decreasing foil thickness when the foils are thinner than a certain value (1 mm for lead foil for 15 MV); (c) decreases with decreasing incident photon‐beam energies; (d) changes slightly for beam incident angles less than 45° and more prominently for larger angles; (e) increases with size of foil; and (f) is almost independent of the depth at which the foil is situated when the foil is placed beyond the range of secondary electrons. The dose enhancement calculation is also performed for a cylindrically shaped lead foil irradiated by a four‐field‐box. The dose enhancement of 34%/13% was obtained at 0.25/2 mm away from the cylindrical outer interface for a 15 MV four‐field‐box.Keywords
This publication has 32 references indexed in Scilit:
- Forward dose perturbation at high atomic number interfaces in kilovoltage x-ray beamsMedical Physics, 1997
- Dose perturbations at interfaces in photon beams: Secondary electron transportMedical Physics, 1990
- Validity of transition‐zone dosimetry at high atomic number interfaces in megavoltage photon beamsMedical Physics, 1990
- Dose enhancement in buildup region by lead, aluminum, and lucite absorbers for 15 MVp photon beamMedical Physics, 1989
- Interface dose perturbation as a measure of megavoltage photon beam energyMedical Physics, 1988
- Dose perturbations at interfaces in photon beamsMedical Physics, 1987
- The Monte Carlo simulation of ion chamber response to60Co-resolution of anomalies associated with interfacesPhysics in Medicine & Biology, 1985
- Perturbation of cobalt 60 radiation doses by metal objects implanted during oral and maxillofacial surgeryJournal of Oral and Maxillofacial Surgery, 1984
- The absorbed dose in the vicinity of an interface between two media irradiated by a60Co sourceThe British Journal of Radiology, 1979
- Dosimetry at Interfaces for High Energy X and Gamma RaysThe British Journal of Radiology, 1966