Systematic use of a collagen‐based vascular closure device immediately after cardiac catheterization procedures in 1,317 consecutive patients
- 26 November 2002
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 57 (4) , 486-495
- https://doi.org/10.1002/ccd.10254
Abstract
Despite recent advances in interventional cardiology, vascular access complications continue to be a significant problem. Conventional manual compression of the femoral access site is associated with prolonged immobilization and significant patient discomfort. We investigated the performance of a collagen‐based closure device applied immediately after catheterization and its complication rate in 1,317 consecutive patients undergoing cardiac catheterization or coronary angioplasty. Patients undergoing coronary angioplasty (n = 644) received more heparin than patients with diagnostic cardiac catheterization (n = 673; 9,675 ± 1,144 IU vs. 6,419 ± 2,211 IU; P < 0.0001). Deployment success rates of the closure device were comparable for patients undergoing diagnostic vs. interventional procedures (95.8% vs. 96.7%; P = 0.46). Complete hemostasis immediately after deployment of the device was achieved in > 90% of all patients, but was lower in the interventional group (93.7% vs. 90.6%; P = 0.05). Major complications including any vascular surgery, major bleeding requiring transfusion, retroperitoneal hematoma, thrombosis or loss of distal pulses, groin infections, significant groin hematoma, and death were observed in 0.53% of all patients, with no differences between diagnostic or interventional patients (0.62% vs. 0.45%; P = 0.953). Subgroup analysis revealed female gender as a predictor of access site complications. Systematic sealing of femoral access sites after both diagnostic and interventional procedures allows for immediate sheath removal with reliable hemostasis. The use of a collagen‐based closure device is associated with a low rate of clinically significant complications. Cathet Cardiovasc Intervent 2002;57:486–495.Keywords
This publication has 39 references indexed in Scilit:
- Systematic use of transradial approach or suture of the femoral artery after angioplasty: Attempt at achieving zero access site complicationsCatheterization and Cardiovascular Interventions, 2000
- Infectious complications related to the use of the Angio-Seal hemostatic puncture closure deviceCatheterization and Cardiovascular Interventions, 1999
- Efficacy and Safety of a Hemostatic Puncture Closure Device With Early Ambulation After Coronary AngiographyThe American Journal of Cardiology, 1998
- Mobilization Within Thirty Minutes of Elective Diagnostic Coronary Angiography: A Feasibility Study Using a Hemostatic Femoral Puncture Closure DeviceJournal of Interventional Cardiology, 1997
- Predictors of groin complications after balloon and new-device coronary interventionThe American Journal of Cardiology, 1995
- Immediate arterial hemostasis after cardiac catheterization: Initial experience with a new puncture closure deviceCatheterization and Cardiovascular Diagnosis, 1994
- A new hemostatic puncture closure device for the immediate sealing of arterial puncture sitesThe American Journal of Cardiology, 1993
- In-hospital costs associated with new percutaneous coronary devicesThe American Journal of Cardiology, 1991
- Early ambulation after 5 French diagnostic cardiac catheterization: Results of a multicenter trialJournal of the American College of Cardiology, 1990
- Safety of outpatient cardiac catheterizationsThe American Journal of Cardiology, 1985