Characterization and Performance of MALDI on a Triple Quadrupole Mass Spectrometer for Analysis and Quantification of Small Molecules
- 5 August 2005
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (17) , 5643-5654
- https://doi.org/10.1021/ac0506130
Abstract
The usefulness of MALDI for small-molecule work has been limited by matrix chemical interference in the mass range of interest, tedious sample preparation, and various crystallization and sample deposition issues. We report instrument characterization and small-molecule quantification performance data from a high repetition rate laser MALDI ion source coupled to a triple quadrupole mass spectrometer. The high repetition rate laser improves sensitivity and precision and allows a proportional increase in sample throughput. Tandem mass spectrometry is used to discriminate the signal from the high chemical background caused by the MALDI matrix. Successful quantification requires use of an internal standard and a means of sample cleanup for typical in vitro sample compositions. This instrument combination and analysis technique is relatively insensitive to sample crystal quality and spot homogeneity. Quantitative performance results are characterized for 53 small-molecule pharmaceutical compounds and compared to those obtained by ESI-MS/MS. Further comparison between MALDI and ESI is examined, and the potential for high-throughput MALDI-MS/MS quantification is demonstrated.Keywords
This publication has 13 references indexed in Scilit:
- Quantitative analysis of small pharmaceutical drugs using a high repetition rate laser matrix-assisted laser/desorption ionization sourceRapid Communications in Mass Spectrometry, 2003
- A High Repetition Rate (1 kHz) Microcrystal Laser for High Throughput Atmospheric Pressure MALDI-Quadrupole-Time-of-Flight Mass SpectrometryAnalytical Chemistry, 2002
- Small molecule analysis by MALDI mass spectrometryAnalytical and Bioanalytical Chemistry, 2002
- Matrix-assisted ultraviolet laser desorption of non-volatile compoundsPublished by Elsevier ,2001
- A High-Capacity LC/MS System for the Bioanalysis of Samples Generated from Plate-Based Metabolic ScreeningAnalytical Chemistry, 2001
- Optimisation of the quantitative determination of chlormequat by matrix‐assisted laser desorption/ionisation mass spectrometryRapid Communications in Mass Spectrometry, 2001
- AutoScan: an automated workstation for rapid determination of mass and tandem mass spectrometry conditions for quantitative bioanalytical mass spectrometryRapid Communications in Mass Spectrometry, 2000
- Quantitative analysis of low molecular weight compounds of biological interest by matrix‐assisted laser desorption ionizationRapid Communications in Mass Spectrometry, 1993
- Mass spectrometry of synthetic polymers by UV-matrix-assisted laser desorption/ionizationAnalytical Chemistry, 1992
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988