Consistent pattern of elevated symptoms in air-conditioned office buildings: a reanalysis of epidemiologic studies.
- 1 October 1990
- journal article
- research article
- Published by American Public Health Association in American Journal of Public Health
- Vol. 80 (10) , 1193-1199
- https://doi.org/10.2105/ajph.80.10.1193
Abstract
Published studies of the relation between type of building ventilation system and work-related symptom prevalence in office workers have been contradictory. A reanalysis was performed of six studied meeting specific eligibility criteria, combining published data with unpublished information obtained from study authors. Five eligible studies were from the United Kingdom, and one was from Denmark. Standardized categories of building ventilation type were created to allow comparison of effects across studies. Within each study, prevalence odds ratios (PORs) were calculated for symptoms in each ventilation category relative to a baseline category of naturally ventilated buildings. Air-conditioned buildings were consistently associated with increased prevalence of work-related headache (POR = 1.3-3.1), lethargy (POR = 1.4-5.1), and upper respiratory/mucus membrane symptoms (POR = 1.3-4.8). Humidification was not a necessary factor for the higher symptom prevalence associated with air-conditioning. Mechanical ventilation without air-conditioning was not associated with higher symptom prevalence. The consistent associations found between type of building ventilation and reported symptom prevalence have potentially important public health and economic implications.This publication has 27 references indexed in Scilit:
- Work-related illness in offices: A proposed model of the “sick building syndrome”Environment International, 1989
- SICK BUILDING SYNDROME: A STUDY OF 4373 OFFICE WORKERSAnnals of Occupational Hygiene, 1987
- Health effects from indoor air pollution: Case studiesJournal of Community Health, 1987
- Demonstration of Microorganisms and Dust in Schools and OfficesAllergy, 1986
- Building related illnessClinical and Experimental Allergy, 1986
- Evaluation of Building Ventilation SystemsAihaj Journal, 1986
- Indirect health effects of relative humidity in indoor environments.Environmental Health Perspectives, 1986
- Comparison of health problems related to work and environmental measurements in two office buildings with different ventilation systems.BMJ, 1985
- THE CONTROL OF MICROBIOLOGICAL HAZARDS ASSOCIATED WITH AIR-CONDITIONING AND VENTILATION SYSTEMS *Annals of Occupational Hygiene, 1983
- The effects of reduced ventilation on indoor air quality in an office buildingAtmospheric Environment (1967), 1983