Inappropriate Sinus Tachycardia After Radiofrequency Ablation of Para‐Hisian Accessory Pathways
- 1 December 1997
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 8 (12) , 1357-1365
- https://doi.org/10.1111/j.1540-8167.1997.tb01032.x
Abstract
Inappropriate sinus tachycardia (IST) has been observed following radiofrequency ablation (RFA) of the AV nodal fast pathway. This study was aimed to prospectively analyze the incidence and clinical significance of IST following RFA of para-Hisian accessory pathways (APs). Twenty-eight patients (pts) with para-Hisian APs underwent RFA. An AP was defined as para-Hisian whenever its atrial and ventricular insertions were associated with a His-bundle potential > or = 0.1 mV. RF current was always delivered at the atrial aspect of the tricuspid annulus, to a site where the His-bundle potential was < 0.15 mV. Time- and frequency-domain analysis of heart rate variability was performed in 22 patients, before and after RFA. Abolition of AP conduction was obtained in all pts, and no AV conduction alteration occurred. Six pts (21.4%) presented with IST 45 to 240 minutes after the ablation procedure. In 5 of them, IST disappeared spontaneously within 72 hours, whereas in 1 pt beta-blockers were required for 2 months. The atrial potential amplitude (1.217 +/- 0.264 mV vs 0.882 +/- 0.173 mV, P = 0.009) and A/V potential amplitude ratio (2.633 vs 1.686, P = 0.05) were significantly higher in pts who developed IST than in those who did not. A marked decrease in heart rate variability was observed only in pts who developed IST. IST is a relatively frequent complication after RFA of para-Hisian APs: it is generally short-lasting and usually does not require any treatment. IST after catheter ablation is likely to depend upon transient parasympathetic denervation of the sinus node.Keywords
This publication has 13 references indexed in Scilit:
- Radiofrequency Catheter Modification of the Sinus Node for “Inappropriate” Sinus TachycardiaCirculation, 1995
- Electrocardiographic characteristics and catheter ablation of parahissian accessory pathways.Circulation, 1994
- Mechanism of 'inappropriate' sinus tachycardia. Role of sympathovagal balance.Circulation, 1994
- Inappropriate Sinus Tachycardia Following Radiofrequency Ablation of AV Nodal Tachycardia: Incidence and Clinical SignificancePacing and Clinical Electrophysiology, 1994
- Alterations of heart rate and of heart rate variability after radiofrequency catheter ablation of supraventricular tachycardia. Delineation of parasympathetic pathways in the human heart.Circulation, 1993
- Persistent inappropriate sinus tachycardia after radiofrequency current catheter modification of the atrioventricular nodeThe American Journal of Cardiology, 1992
- Electrogram criteria for identification of appropriate target sites for radiofrequency catheter ablation of accessory atrioventricular connections.Circulation, 1992
- Cardiovascular neural regulation explored in the frequency domain.Circulation, 1991
- Sites of conduction block in accessory atrioventricular pathways. Basis for concealed accessory pathways.Circulation, 1990
- Optimum AV Interval in Dual Chamber PacemakersPacing and Clinical Electrophysiology, 1986