A Field Investigation of Bacillus anthracis Contamination of U.S. Department of Agriculture and Other Washington, D.C., Buildings during the Anthrax Attack of October 2001
- 1 January 2003
- journal article
- research article
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 69 (1) , 593-599
- https://doi.org/10.1128/aem.69.1.593-599.2003
Abstract
In response to a bioterrorism attack in the Washington, D.C., area in October 2001, a mobile laboratory (ML) was set up in the city to conduct rapid molecular tests on environmental samples for the presence of Bacillus anthracis spores and to route samples for further culture analysis. The ML contained class I laminar-flow hoods, a portable autoclave, two portable real-time PCR devices (Ruggedized Advanced Pathogen Identification Device [RAPID]), and miscellaneous supplies and equipment to process samples. Envelopes and swab and air samples collected from 30 locations in the metropolitan area once every three days were subjected to visual examination and DNA extraction, followed by real-time PCR using freeze-dried, fluorescent-probe-based reagents. Surface swabs and air samples were also cultured for B. anthracis at the National Veterinary Service Laboratory (NVSL) in Ames, Iowa. From 24 October 2001 to 15 September 2002, 2,092 pieces of mail were examined, 405 real-time PCR assays were performed (comprising 4,639 samples), and at the NVSL 6,275 samples were subjected to over 18,000 platings. None of the PCR assays on DNA extracted from swab and air samples were positive, but viable spores were cultured from surface swabs taken from six locations in the metropolitan area in October, November, and December 2001 and February, March, and May 2002. DNA extracted from these suspected B. anthracis colonies was positive by real-time and conventional PCRs for the lethal factor, pXO1, and for capA and vrr genes; sequence analysis of the latter amplicons indicated >99% homology with the Ames, vollum, B6273-93, C93022281, and W-21 strains of B. anthracis , suggesting they arose from cross-contamination during the attack through the mail. The RAPID-based PCR analysis provided fast confirmation of suspect colonies from an overnight incubation on agar plates.Keywords
This publication has 7 references indexed in Scilit:
- From the Centers for Disease Control and Prevention. Evaluation of Bacillus anthracis contamination inside the Brentwood mail processing and distribution center--District of Columbia, October 2001.2002
- Use of onsite technologies for rapidly assessing environmental Bacillus anthracis contamination on surfaces in buildings.2001
- Detection of anthrax spores from the air by real-time PCRLetters in Applied Microbiology, 2001
- Utilization of the rpoB Gene as a Specific Chromosomal Marker for Real-Time PCR Detection of Bacillus anthracisApplied and Environmental Microbiology, 2001
- Bacillus Spore Inactivation Methods Affect Detection AssaysApplied and Environmental Microbiology, 2001
- PCR analysis of tissue samples from the 1979 Sverdlovsk anthrax victims: The presence of multiple Bacillus anthracis strains in different victimsProceedings of the National Academy of Sciences, 1998
- Identification of a region of genetic variability among Bacillus anthracis strains and related speciesJournal of Bacteriology, 1996