Spiral CT Angiography of the Renal Arteries: Should a Scan Delay Based on a Test Bolus Injection or a Fixed Scan Delay Be Used to Obtain Maximum Enhancement of the Vessels?
- 1 July 1998
- journal article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 22 (4) , 541-547
- https://doi.org/10.1097/00004728-199807000-00008
Abstract
The purpose of this work was to assess the optimal scan delay for spiral CT angiography (SCTA) of the renal arteries in achieving optimal vascular contrast enhancement and to compare the utility of a delay based on these bolus injection versus that of a fixed scan delay. Seventy patients underwent renal artery SCTA with a 140 ml bolus of contrast agent injected a 3 ml/s. In 35 patients (Group A), a fixed scan delay of 27 s was used; in the other 35 (Group B), the scan delay was based on the transit time (TTest) of a test bolus injection. The scan delays in this group were set at TTest + 5 s (n = 5), TTest + 10 s (n = 8), TTest + 15 s (n = 4), or TTest + 20 s (n = 18). For all 70 patients, the time intervals between TRA (time to scanning the renal arteries) and TMax (time to maximum aortic enhancement after 140 ml bolus injection) were calculated, after which it was determined in which group of patients TRA occurred closest to TMax. Linear regression and mean squared error (MSE) were used for statistical analysis. For Group A, mean TRA and TMax were 38 and 50 s, respectively. Mean (TRA - TMax) was -12 s with MSE of 185.76. For Group B, mean TRA and Tmax were 45 and 52 s. Mean (TRA - TMax) values were -15, -12, -11, and -1 s for scan delays of TTEST + 5 s, TTEST + 10 s, TTest + 15 s, and TTEST + 20 s, respectively, with MSEs of 253.80, 158.00, 137.50, and 30.00. SCTA of the renal arteries was best performed with a scan delay of TTEST + 20 s. However, analysis of our data showed that similar results could be expected with a delay of 44 s.Keywords
This publication has 12 references indexed in Scilit:
- Helical CT angiography compared with arteriography in the detection of renal artery stenosis.American Journal of Roentgenology, 1996
- Helical CT of the liver: clinical application of an automated computer technique, SmartPrep, for obtaining images with optimal contrast enhancement.American Journal of Roentgenology, 1995
- Determination of Scan Delay Time in Spiral CT-AngiographyJournal of Computer Assisted Tomography, 1995
- Hepatic CT enhancement. Part I. Alterations in the volume of contrast material within the same patients.Radiology, 1994
- Spiral CT of renal artery stenosis: comparison of three-dimensional rendering techniques.Radiology, 1994
- Renal arterial stenoses: spiral CT angiography.Radiology, 1993
- Spiral CT Evaluation of Coronary Artery Bypass Graft PatencyJournal of Computer Assisted Tomography, 1993
- Three-dimensional spiral CT angiography of the abdomen: initial clinical experience.Radiology, 1993
- Bolus geometry and dynamics after intravenous contrast medium injection.Radiology, 1984
- Some suggestions for measuring predictive performanceJournal of Pharmacokinetics and Biopharmaceutics, 1981