Improved method for peak picking in matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry
- 28 April 2004
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 18 (11) , 1208-1212
- https://doi.org/10.1002/rcm.1467
Abstract
A method for peak picking for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is described. The method is based on the assumption that two sets of ions are formed during the ionization stage, which have Gaussian distributions but different velocity profiles. This gives rise to a certain degree of peak skewness. Our algorithm deconvolutes the peak and utilizes the fast velocity, bulk ion distribution for peak picking. Evaluation of the performance of the new method was conducted using peptide peaks from a bovine serum albumin (BSA) digest, and compared with the commercial peak-picking algorithms Centroid and SNAP. When using the new two-Gaussian algorithm, for strong signals the mass accuracy was equal to or marginally better than the results obtained from the commercial algorithms. However, for weak, distorted peaks, considerable improvement in both mass accuracy and precision was obtained. This improvement should be particularly useful in proteomics, where a lack of signal strength is often encountered when dealing with weakly expressed proteins. Finally, since the new peak-picking method uses information from the entire signal, no adjustments of parameters related to peak height have to be made, which simplifies its practical use. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 18 references indexed in Scilit:
- On the formation of initial ion velocities in matrix-assisted laser desorption ionization: Virtual desorption time as an additional parameter describing ion ejection dynamicsInternational Journal of Mass Spectrometry, 2003
- Sample preparation protocols for MALDI-MS of peptides and oligonucleotides using prestructured sample supportsInternational Journal of Mass Spectrometry, 2003
- The Desorption Process in MALDIChemical Reviews, 2003
- An improved two‐step calibration method for matrix‐assisted laser desorption/ionization time‐of‐flight mass spectra for proteomicsRapid Communications in Mass Spectrometry, 2002
- Radial velocity distributions of molecular ions produced by matrix-assisted laser desorption/ionizationInternational Journal of Mass Spectrometry and Ion Processes, 1997
- Mass Resolution Improvement by Incorporation of Pulsed Ion Extraction in a Matrix-Assisted Laser Desorption/Ionization Linear Time-of-Flight Mass SpectrometerAnalytical Chemistry, 1995
- Influence of the laser intensity and spot size on the desorption of molecules and ions in matrix-assisted laser desorption/ionization with a uniform beam profileInternational Journal of Mass Spectrometry and Ion Processes, 1995
- Laser assisted reflectron time-of-flight mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1994
- Properties of matrix‐assisted laser desorption. Measurements with a time‐to‐digital converterRapid Communications in Mass Spectrometry, 1991
- Microchannel plate detectorsNuclear Instruments and Methods, 1979