Analysis of permanent magnet synchronous motors
- 1 January 1991
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 27 (2) , 350-354
- https://doi.org/10.1109/28.73625
Abstract
A detailed representation of buried permanent magnet synchronous motors at steady state is presented. An equivalent circuit is proposed that accounts for the saliency of the machine and for the particular influence of iron core losses on the machine operations. Both no-load and loaded conditions are analyzed and experimentally tested in order to describe the influence of the armature current on the rotor flux distribution. Experimental tests on a 2 HP buried permanent magnet machine are presented to validate the proposed approach.Keywords
This publication has 5 references indexed in Scilit:
- Power capability of salient pole permanent magnet synchronous motors in variable speed drive applicationsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Core loss in buried magnet permanent magnet synchronous motorsIEEE Transactions on Energy Conversion, 1989
- Interior type permanent magnet synchronous motor analysis by equivalent circuitsIEEE Transactions on Energy Conversion, 1989
- Interior Permanent-Magnet Synchronous Motors for Adjustable-Speed DrivesIEEE Transactions on Industry Applications, 1986
- Transient Performance of Permanent Magnet AC Motor DrivesIEEE Transactions on Industry Applications, 1986