UHMW-Polyethylen als Werkstoff für artikulierende Komponenten von Gelenkendoprothesen. UHMW Polyethylene Used as a Material for the Articulating Components of Endoprostheses
- 1 January 1993
- journal article
- Published by Walter de Gruyter GmbH in Biomedizinische Technik/Biomedical Engineering
- Vol. 38 (12) , 303-313
- https://doi.org/10.1515/bmte.1993.38.12.303
Abstract
In recent years there has been an increase in the incidence of problems with UHMWPE used in implants. In particular the risk of osteolysis and loosening resulting from the body's reactions to polyethylene wear particles must be eliminated. A variety of investigations with UHMWPE provided hints on how to improve the quality of the original material, machining and reduction of contaminants, which have since been implemented. The knowledge gained of the visco-elastic behaviour of this polymer makes it possible to optimize the design of implant components. The need to sterilize the component parts with ionizing radiation results in changes in the structure of UHMWPE. Via oxidation and acceleration of the ageing process of the material, irradiation in air reduces the molecular weight, which is important for the tribological properties. The use of a nitrogen atmosphere during irradiation and for storage makes it possible to take advantage of the positive effects of this method of sterilization via cross-linking of the polyethylene. Positive ductile properties are thus maintained and the resistance to wear is increased. An investigation of 134 components explanted during re-operation revealed a wide scatter in the results of wear. One of the reasons for increased polyethylene wear is the additional abrasive effect of particles of bone cement that get into the space between the articulating components; this can be minimized by a meticulous cementing technique.Keywords
This publication has 5 references indexed in Scilit:
- Quality of the Surface Finish of the Head of the Femoral Component and the Wear Rate of the Socket in Long-Term Results of the Charnley Low-Friction ArthroplastyProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1992
- Stress distributions in the acetabular region—I. Before and after total joint replacementJournal of Biomechanics, 1982
- Effect of radiation sterilization and aging on ultrahigh molecular weight polyethyleneJournal of Biomedical Materials Research, 1981
- Cold compaction molding and sintering of ultra high molecular weight polyethylenePolymer Engineering & Science, 1980
- Das Verhalten von Hochpolymeren gegenüber energiereicher StrahlungColloid and Polymer Science, 1966