Column-switching high-performance liquid chromatography electrospray mass spectrometry coupled with on-line of extraction for the determination of mono- and di-(2-ethylhexyl) phthalate in blood samples
- 29 January 2003
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 375 (4) , 527-533
- https://doi.org/10.1007/s00216-002-1709-9
Abstract
A novel method based on column-switching high-performance liquid chromatography–electrospray mass spectrometry (LC–MS) coupled with an on-line extraction column containing conjugated avidin has been developed for direct injection analysis of di(2-ethylhexyl) phthalate (DEHP) and its metabolite, mono(2-ethylhexyl) phthalate (MEHP), in blood samples. The sample preparation for on-line extraction involved the mixing of blood samples with internal standards, DEHP-d4 and MEHP-d4, in LC glass vials. A linear response was found for column-switching LC–MS when tests were conducted within the validated range of 25 to 1000 ng mL–1 for DEHP and 5 to 1000 ng mL–1 for MEHP, with correlation coefficients (r) greater than 0.999. In addition, the recoveries of DEHP and MEHP from human plasma were calculated by using this method with on-line extraction, yielding recoveries of up to 91.2% (RSD–1 for DEHP, and N.D. is –1 for MEHP). In contrast, high DEHP contamination of commercially available fetal bovine serum samples was found by this method.Keywords
This publication has 24 references indexed in Scilit:
- Phthalate Esters Detected in Various Water Samples and Biodegradation of the Phthalates by Microbes Isolated from River Water.Biological & Pharmaceutical Bulletin, 2002
- Monitoring of Phthalic Acid Monoesters in River Water by Solid-Phase Extraction and GC-MS DeterminationEnvironmental Science & Technology, 2001
- High-performance liquid chromatographic method for the determination of di(2-ethylhexyl) phthalate in total parenteral nutrition and in plasmaJournal of Chromatography B: Biomedical Sciences and Applications, 2001
- No background concentrations of di(2-ethylhexyl) phthalate and mono(2-ethylhexyl) phthalate in blood of ratsArchives of Toxicology, 2001
- The clinical effects of plasticizers, antioxidants, and other contaminants in medical polyvinylchloride tubing during respiratory and non-respiratory exposureClinica Chimica Acta; International Journal of Clinical Chemistry, 2001
- Health risks posed by use of Di-2-ethylhexyl phthalate (DEHP) in PVC medical devices: A critical reviewAmerican Journal of Industrial Medicine, 2001
- Investigation of the release behavior of diethylhexyl phthalate from the polyvinyl-chloride tubing for intravenous administrationInternational Journal of Pharmaceutics, 2000
- Quantitative Detection of Eight Phthalate Metabolites in Human Urine Using HPLC−APCI-MS/MSAnalytical Chemistry, 2000
- Chromatographic fractionation and analysis by mass spectrometry of conjugated metabolites of bis(2-ethylhexyl)phthalate in urineJournal of Chromatography B: Biomedical Sciences and Applications, 1996
- Liquid chromatographic determination of the plasticizer di(2-ethylhexyl) phthalate (DEHP) in PVC plasticsAnalytical and Bioanalytical Chemistry, 1994