Long wavelength fluorophores and cell‐by‐cell correction for autofluorescence significantly improves the accuracy of flow cytometric energy transfer measurements on a dual‐laser benchtop flow cytometer
- 27 June 2002
- Vol. 48 (3) , 124-135
- https://doi.org/10.1002/cyto.10121
Abstract
Flow cytometric fluorescence resonance energy transfer (FCET) is an efficient method to map associations between biomolecules because of its high sensitivity to changes in molecular distances in the range of 1–10 nm. However, the requirement for a dual-laser instrument and the need for a relatively high signal-to-noise system (i.e., high expression level of the molecules) pose limitations to a wide application of the method. Antibodies conjugated to cyanines 3 and 5 (Cy3 and Cy5) were used to label membrane proteins on the cell surface. FCET measurements were made on a widely used benchtop dual-laser flow cytometer, the FACSCalibur, by using cell-by-cell analysis of energy transfer efficiency. To increase the accuracy of FCET measurements, we applied a long wavelength donor–acceptor pair, Cy3 and Cy5, which beneficially affected the signal-to-noise ratio in comparison with the classic pair of fluorescein and rhodamine. A new algorithm for cell-by-cell correction of autofluorescence further improved the sensitivity of the technique; cell subpopulations with only slightly different FCET efficiencies could be identified. The new FCET technique was tested on various direct and indirect immunofluorescent labeling strategies. The highest FCET values could be measured when applying direct labeling on both (donor and acceptor) sides. Upon increasing the complexity of the labeling scheme by introducing secondary antibodies, we detected a decrease in the energy transfer efficiency. We developed a new FCET protocol by applying long wavelength excitation and detection of fluorescence and by refining autofluorescence correction. The increased accuracy of the new method makes cells with low receptor expression amenable to FCET investigation, and the new approach can be implemented easily on a commercially available dual-laser flow cytometer, such as a FACSCalibur. Cytometry 48:124–135, 2002.Keywords
Funding Information
- European Commission (FP 5 QLRT-1999-3126)
- Hungarian-British Joint Academic and Research Programme (069)
- Hungarian Academy of Sciences (OTKA 303999)
- Hungarian Ministry of Health (ETT 07-461, ETT 117/2001)
- Hungarian Ministry of Education (FKFP 0607)
This publication has 31 references indexed in Scilit:
- Grafting primary human T lymphocytes with cancer-specific chimeric single chain and two chain TCRGene Therapy, 2000
- Imaging Protein Kinase Cα Activation in CellsScience, 1999
- Use of fluorescent europium chelates as labels in microscopy allows glutaraldehyde fixation and permanent mounting and leads to reduced autofluorescence and good long‐term stabilityMicroscopy Research and Technique, 1994
- Immunofluorescence analysis in flow cytometry: better selection of antibody-labeled cells after fluorescence overcompensation in the red channel.Journal of Histochemistry & Cytochemistry, 1991
- Correction of cellular autofluorescence in flow cytometry by mathematical modeling of cellular fluorescenceCytometry, 1988
- An improved immunocytochemical procedure for high‐sensitivity detection of incorporated bromodeoxyuridineCytometry, 1987
- Flow cytometric measurements of fluorescence energy transfer using single laser excitationCytometry, 1987
- Comparison of helium-neon and dye lasers for the excitation of allophycocyaninCytometry, 1987
- Autofluorescence of viable cultured mammalian cells.Journal of Histochemistry & Cytochemistry, 1979