The effect of surface preparation on metal/bone cement interfacial strength
- 1 June 1987
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 21 (6) , 773-805
- https://doi.org/10.1002/jbm.820210607
Abstract
This study is concerned with finding practical ways for strengthening metal/bone cement (M/BC) interfaces via surface alterations and identifying fundamental mechanisms underlying M/BC adherence. Shear strengths have been inferred from torsion tests using shear lag analysis. The variables examined with regard to their effects on interfacial strength are substrate material, surface roughness, interface porosity, passivation and sterilization, surface cleaning procedures, and use of bone cement precoated metals. M/BC interfaces can be substantially strengthened by applying the bone cement to the metal with high pressure. This would be a practical way to strengthen interfaces for precoated implants. The acrylic polymerized in vivo would employ the usual low pressure method. Otherwise, the main method for improving M/BC interfaces is through changing surface topography. Cleaning or chemical treatments have relatively minor effects. Roughened surfaces, as expected, produce stronger interfaces. Dramatic strength improvements occurred with a porous arc plasma sprayed layer on the substrate. Surprisingly, highly polished surfaces also improve interface strength (compared to less polished surfaces). The hypothesis is advanced that M/BC adherence depends upon superposition of mechanical interlocking and atomic interaction effects, with the latter predominating for finer finishes and vice versa. Differences exist between materials which are independent of roughness.This publication has 39 references indexed in Scilit:
- Retrieval Analysis of Total Joint Replacement Components: A Six-Year ExperiencePublished by ASTM International ,1985
- Intramedullary fixation of artificial hip joints with bone cement-precoated implants. II. Density and histological studyJournal of Biomedical Materials Research, 1982
- A Radiographic Analysis of 166 Charnley-M$uUller Total Hip ArthroplastiesPublished by Wolters Kluwer Health ,1982
- Transient and Residual Stresses and Displacements in Self-Curing Bone Cement—Part II: Thermoelastic Analysis of the Stem Fixation SystemJournal of Biomechanical Engineering, 1982
- Transient and Residual Stresses and Displacements in Self-Curing Bone Cement—Part I: Characterization of Relevant Volumetric Behavior of Bone CementJournal of Biomechanical Engineering, 1982
- A model femur for in vitro testing of femoral componentsJournal of Biomedical Engineering, 1981
- Evaluation of acrylic bone cements and their performance standardsJournal of Biomedical Materials Research, 1981
- The Formation of Stress by Acrylic Bone Cements During Fixation of the Acetabular ProsthesisActa Orthopaedica, 1980
- Load actions transmitted by implantsJournal of Biomedical Engineering, 1979
- Thermoelastic Constitutive Equations for Chemically Hardening MaterialsJournal of Applied Mechanics, 1974