Use of Recovery-enhanced Thermography to Localize Cutaneous Perforators
- 1 May 1995
- journal article
- case report
- Published by Wolters Kluwer Health in Annals of Plastic Surgery
- Vol. 34 (5) , 507-511
- https://doi.org/10.1097/00000637-199505000-00009
Abstract
Recovery-enhanced thermography implies the scanning, after cooling, of the skin surface with ice water for several seconds. Using this method, cutaneous perforators were clearly identified in constant distributions on the trunks of 12 healthy volunteers. Clinically, preoperative recovery-enhanced thermography is useful for the design of perforator-based flaps. We describe this method in detail and demonstrate its reliability with successful clinical cases.Keywords