Abstract
The first order anisotropy field strength of sintered orientated NdFeB samples is determined by transverse susceptibility measurement. It is shown that this method yields reliable data, even if the applied field is much smaller than the anisotropy field to be detected. Systematic and technical error sources are discussed on the basis of calculation results.

This publication has 4 references indexed in Scilit: