Evaluation of a spasmolytic cocktail to prevent radial artery spasm during coronary procedures
- 19 February 2003
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 58 (3) , 281-284
- https://doi.org/10.1002/ccd.10445
Abstract
Radial artery spasm is a frequent complication of the transradial approach for coronary angiography and angioplasty. Recently, we have been able to quantify spasm using the automatic pullback device. The objective of this study was to assess the efficacy of an intra‐arterial vasodilating cocktail in reducing the incidence and severity of radial artery spasm. A hundred patients undergoing coronary procedures via the radial artery were divided into two groups of 50 each. Patients in group A received intra‐arterial cocktail (5 mg of verapamil plus 200 μg nitroglycerine in 10 ml of normal saline), while patients in group B did not receive any vasodilating drug. The pullback device was used for sheath removal at the end of the procedure. Seven (14%) patients in group A experienced pain (i.e., pain score of III–V) during automatic sheath removal, as compared to 17 (34%) in group B (P = 0.019). The mean pain score was significantly lower in group A than in group B (1.7 ± 0.94 vs. 2.08 ± 1.07; P = 0.03). The maximal pullback force (MPF) was also significantly lower for group A (0.53 ± 0.52 kg; range, 0.10–3.03 kg) as compared to group B (0.76 ± 0.45 kg; range, 0.24–1.99 kg; P = 0.013). Only 4 (8%) patients in group A had an MPF value greater than 1.0 kg, suggesting the presence of significant radial artery spasm, as opposed to 11 (22%) in group B (P = 0.029). Administration of an intra‐arterial vasodilating cocktail prior to sheath insertion reduces the occurrence and severity of radial artery spasm. Cathet Cardiovasc Intervent 2003;58:281–284.Keywords
This publication has 13 references indexed in Scilit:
- Reduction of discomfort at sheath removal during transradial coronary procedures with the use of a hydrophilic-coated sheathCatheterization and Cardiovascular Interventions, 2001
- Learning curve in the use of the radial artery as vascular access in the performance of percutaneous transluminal coronary angioplastyCatheterization and Cardiovascular Diagnosis, 1998
- Verapamil plus nitroglycerin solution maximally preserves endothelial function of the radial artery: Comparison with papaverine solutionThe Journal of Thoracic and Cardiovascular Surgery, 1998
- Coronary angiography from the radial artery – experience, complications and limitationsInternational Journal of Cardiology, 1998
- Characteristics of adrenoceptors in the human radial artery: Clinical implicationsThe Journal of Thoracic and Cardiovascular Surgery, 1998
- A Randomized Comparison of Percutaneous Transluminal Coronary Angioplasty by the Radial, Brachial and Femoral Approaches: The Access StudyJournal of the American College of Cardiology, 1997
- Outpatient Coronary Stent ImplantationJournal of the American College of Cardiology, 1997
- Use of verapamil and nitroglycerin solution in preparation of radial artery for coronary graftingThe Annals of Thoracic Surgery, 1996
- Comparison among arterial grafts and coronary artery: An attempt at functional classificationThe Journal of Thoracic and Cardiovascular Surgery, 1995
- Transradial artery coronary angioplastyAmerican Heart Journal, 1995