Surfactant-induced sealing of electropermeabilized skeletal muscle membranes in vivo.
- 15 May 1992
- journal article
- Published by Proceedings of the National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 89 (10) , 4524-4528
- https://doi.org/10.1073/pnas.89.10.4524
Abstract
Victims of major electrical trauma frequently suffer extensive skeletal muscle and nerve damage, which is postulated to be principally mediated by electroporation and/or thermally driven cell membrane permeabilization. We have investigated the efficacy of two blood-compatible chemical surfactants for sealing electroporated muscle membranes. In studies using cultured skeletal muscle cells, poloxamer 188 (P188; an 8.4-kDa nonionic surfactant) blocks, and neutral dextran (10.1 kDa) substantially retards, carboxyfluorescein release from electropermeabilized cell membranes. To test whether P188 administered intravenously could have the same therapeutic effect in vivo, the rat biceps femoris muscle flap attached by its arteriovenous pedicle was electropermeabilized until its electrical resistivity dropped to 50% of the initial value. P188 (460 mg/kg) administered intravenously 20 min postshock restored the resistivity to 77% of the initial value. When P188 was administered intravenously 5 min before shock, a dose-dependent impedance recovery rate was observed. Neither neutral dextran (460 mg/kg) nor sterile saline was effective. Histopathologic studies indicated that postshock poloxamer administration reduced tissue inflammation and damage in comparison with dextran-treated or control tissues. Electrophysiologic evidence of membrane damage was not observed in flaps of animals pretreated with poloxamer. These results suggest that it may be possible to seal in vivo tissue membranes injured by electrical, thermal, or other membrane-damaging forces.Keywords
This publication has 10 references indexed in Scilit:
- Rhabdomyolysis Due to Pulsed Electric FieldsPlastic and Reconstructive Surgery, 1990
- Role of cell membrane rupture in the pathogenesis of electrical traumaJournal of Surgical Research, 1988
- Electrical injury mechanisms: dynamics of the thermal response.1987
- Electrical Injury MechanismsPlastic and Reconstructive Surgery, 1987
- Proliferation of muscle satellite cells on intact myofibers in cultureDevelopmental Biology, 1986
- Measure of Tissue Resistivity in Experimental Electrical BurnsPublished by Wolters Kluwer Health ,1985
- Pluronic F-68: A promising new skin wound cleanserAnnals of Emergency Medicine, 1980
- Interaction of neutral polysaccharides with phosphatidylcholine multilamellar liposomes. Phase transitions studied by the binding of fluorescein-conjugated dextransBiochemistry, 1979
- Electroviscous Effect in Dextran-Erythrocyte SuspensionsNature New Biology, 1972
- Electrical injuries: a review of 65 cases.1969