Patient-derived Quality Specifications for Instruments Used in Self-Monitoring of Blood Glucose
- 1 January 2001
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 47 (1) , 67-73
- https://doi.org/10.1093/clinchem/47.1.67
Abstract
Background: Instruments for self-monitoring of glucose (SMBG) are increasingly used by diabetic patients. Information is limited on how patients use and interpret SMBG results, and no quality specifications for such instruments are based on the opinions of patients. Methods: Type 1 diabetic patients (n = 201) filled in a questionnaire eliciting daily limits for blood glucose (BG) and changes of BG considered significant at different glucose concentrations. From these responses, patient-derived quality specifications were calculated in different clinical situations with low, intermediate, and high BG concentrations. Results: Mean age of the patients was 31.8 years, mean diabetes duration was 14.7 years, and mean SMBG duration was 10.0 years with a mean frequency of 11.2 measurements/week. The threshold for hypoglycemic symptoms was 3.0 mmol/L (54 mg/dL), and the mean daily BG target window was 4.3–10.4 mmol/L (77–187 mg/dL). The mean absolute BG changes producing actions from the patients ranged from 1.1 mmol/L (20 mg/dL) to 3.6 mmol/L (65 mg/dL). The analytical quality specifications for imprecision depended on the clinical situation. Excluding the hypoglycemic situation, the analytical CV needed to fulfill the expectations of 75% of the patients was 6.4–9.7%. The analytical quality specification for CV at hypoglycemic concentrations was 3.1%. Conclusions: Instruments for self-measurements of glucose with an imprecision (CV) of ≤5% and bias ≤5% meet the expectations of >75% of patients in clinical situations other than hypoglycemia.This publication has 21 references indexed in Scilit:
- Quality specifications derived from objective analyses based upon clinical needsScandinavian Journal of Clinical and Laboratory Investigation, 1999
- Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)The Lancet, 1998
- Sell-Monitoring of Blood GlucoseDiabetes Care, 1996
- Patient and Physician Analytic Goals for Self-Monitoring Blood Glucose InstrumentsAmerican Journal of Clinical Pathology, 1994
- What makes people with diabetes measure their own blood glucose?Practical Diabetes International, 1994
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993
- Impact of blood glucose monitoring on diabetic control: Obstacles and interventionsJournal of Behavioral Medicine, 1989
- Generation and Application of Data on Biological Variation in Clinical ChemistryCritical Reviews in Clinical Laboratory Sciences, 1989
- Home Monitors of Blood Glucose: Comparison of Precision and AccuracyDiabetes Care, 1987
- Analytic Precision in Clinical Chemistry and Medical DecisionsAmerican Journal of Clinical Pathology, 1980