Personal monitoring of pregnant staff in diagnostic radiology
- 1 December 1993
- journal article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 13 (4) , 259-265
- https://doi.org/10.1088/0952-4746/13/4/003
Abstract
In order to protect pregnant staff from the hazards of ionising radiation, additional controls are implemented. The International Commission on Radiological Protection have recently recommended that the fetus should be protected by the application of a supplementary dose limit of 2 mSv to the surface of the abdomen for the remainder of the pregnancy, once it has been declared. An experimental investigation was performed to discover the relationship between radiation monitor reading and equivalent dose to the uterus in diagnostic radiology. Tissue equivalent phantoms were used to simulate irradiation conditions typical of those in fluoroscopy. Scattered radiation distributions were produced using primary X-ray beams generated at three tube potentials (70, 90 and 110 kVp) for both overcouch tube and undercouch tube geometries. A further experiment was performed in which the tissue equivalent phantom was irradiated with primary radiation whilst being shielded by a protective apron equivalent to 0.25 mm and 0.33 mm lead. It may be deduced from the results of this investigation that, in the main, during fluoroscopy the application of a 2 mSv dose limit will limit the fetal dose to less than 1 mSv. Finally, a review is presented of those fluoroscopy procedures in which the supplementary dose-limit to the surface of the abdomen may be exceeded.Keywords
This publication has 10 references indexed in Scilit:
- Personal monitoring during fluoroscopyJournal of Radiological Protection, 1992
- Influence of radiologist grade on fluoroscopic patient doseThe British Journal of Radiology, 1992
- The dependence of the scattered radiation dose to personnel on technique factors in diagnostic radiologyThe British Journal of Radiology, 1992
- Broad-beam transmission data in lead for scattered radiation produced at diagnostic energiesThe British Journal of Radiology, 1991
- A survey of the radiation exposures received by the staff at two cardiac catheterization laboratoriesThe British Journal of Radiology, 1990
- In uteroexposure to A-bomb radiation and mental retardation; a reassessmentThe British Journal of Radiology, 1984
- A survey of radiation doses to patients in five common diagnostic examinations. I. Principles and techniques of dose evaluation by indirect measurement II. Survey resultsThe British Journal of Radiology, 1983
- Pregnancy and women radiologists.Radiology, 1982
- An assessment of the radiation dose received by staff using fluoroscopic equipmentThe British Journal of Radiology, 1982
- Personnel exposure to radiation at some angiographic procedures.Radiology, 1981