Response of plastic scintillators in magnetic fields
- 1 April 1990
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 37 (2) , 220-224
- https://doi.org/10.1109/23.106622
Abstract
The dependence of the light yield on magnetic field has been measured up to 0.45 T for the plastic scintillators NE-102A, SCSN-38, and Polivar. The scintillators were excited by 25-MeV protons, 5.9-keV X-rays, and UV light. When excited with ionizing radiation an increase of light yield is observed. For SCSN-38 of 2.7-mm thickness it amounts to 0.3%, 0.9%, 1.1%, and 3.3% at 1, 10, 100 and 450 mT, respectively. Ne-102A behaves similarly whereas a polymethyl methacrylate (PMMA)-based scintillator shows a stronger field dependencKeywords