Evaluation of Linear Array Human Papillomavirus Genotyping Using Automatic Optical Imaging Software
- 1 August 2008
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 46 (8) , 2759-2765
- https://doi.org/10.1128/jcm.00188-08
Abstract
Variations in biological behavior suggest that each carcinogenic human papillomavirus (HPV) type should be considered individually in etiologic studies. HPV genotyping assays might have clinical applications if they are approved for use by the FDA. A widely used genotyping assay is the Roche Linear Array HPV genotyping test (LA). We used LA to genotype the HPV isolates from cervical specimens from women with the full spectrum of cervical disease: cervical cancer, cervical intraepithelial neoplasia (CIN), and HPV infections. To explore the feasibility and value of the automated reading of the LA results, we custom-designed novel, optical imaging software that provides optical density measurements of LA bands. We compared unmagnified visual examination with the automated measurements. The two measurements were highly associated. By either method, the threshold between a negative and a positive result was fairly sharp, with a clear bimodal distribution. Visually, most positive results were judged to be strong or medium, with fewer equivocal results categorized as weak (9.5% of positive samples), very weak (6.5% of positive samples), or extremely weak (7.7% of positive samples). The automated measurements of the intensities were significantly associated with the strength of the visual categories ( P < 0.001). At the extremes of the automated signal intensities (≤20 units or ≥120 units), the bands were almost always categorized visually as negative and positive, respectively. In the equivocal zone (20 to 119 units), specimens were more increasingly likely to be judged to be visually positive as the number of other, definite infections on the same strip increased ( P for trend < 0.001). Multiple, concurrent infections comprise ≥25% of HPV infections; thus, any systematic visual tendency that influences their evaluation when the result is equivocal should be minimized. Therefore, automated reading is probably worth development if easy-to-calibrate hardware and software can be optimized.Keywords
This publication has 12 references indexed in Scilit:
- Rapid Clearance of Human Papillomavirus and Implications for Clinical Focus on Persistent InfectionsJNCI Journal of the National Cancer Institute, 2008
- Human papillomavirus and cervical cancerThe Lancet, 2007
- DNA extraction: An understudied and important aspect of HPV genotyping using PCR-based methodsJournal of Virological Methods, 2007
- Visual appearance of the uterine cervix: correlation with human papillomavirus detection and typeAmerican Journal of Obstetrics and Gynecology, 2007
- A 2‐Year Prospective Study of Human Papillomavirus Persistence among Women with a Cytological Diagnosis of Atypical Squamous Cells of Undetermined Significance or Low‐Grade Squamous Intraepithelial LesionThe Journal of Infectious Diseases, 2007
- Relationships of Human Papillomavirus Type, Qualitative Viral Load, and Age with Cytologic AbnormalityCancer Research, 2006
- Cervical Coinfection with Human Papillomavirus (HPV) Types and Possible Implications for the Prevention of Cervical Cancer by HPV VaccinesThe Journal of Infectious Diseases, 2005
- Epidemiologic Profile of Type‐Specific Human Papillomavirus Infection and Cervical Neoplasia in Guanacaste, Costa RicaThe Journal of Infectious Diseases, 2005
- Epidemiologic Classification of Human Papillomavirus Types Associated with Cervical CancerNew England Journal of Medicine, 2003
- ASCUS-LSIL Triage StudyActa Cytologica, 2000