Two-dimensional (2D) echocardiographic approaches based on geometric assumptions face the greatest limitations and inaccuracies in patients with left ventricular (LV) aneurysms. Three-dimensional (3D) echocardiographic techniques can potentially overcome these limitations; to date, however, although tested in experimental models of aneurysms, they have not been applied to a series of patients with such distortion. The purpose of this study was therefore to validate the clinical application of tomographic 3D echocardiography (3DE) by the routine transthoracic approach to determine LV chamber size and systolic function without geometric assumptions in patients with LV aneurysms. In 23 patients with chronic stable LV aneurysms, LV end-systolic and end-diastolic volumes (LVEDV, LVESV) and ejection fraction (LVEF) by tomographic 3DE were compared with results from 3D magnetic resonance tomography (3DMRT) as an independent reference as well as with the conventional techniques of single plane and biplane 2D echocardiography and biplane cineventriculography. Dynamic 3DE image data sets were obtained from a transthoracic apical view with the use of a rotating probe with acquisition gated to control for ECG and respiration (Echoscan, TomTec). Volumes were calculated from the 3D data sets by summating the volumes of multiple parallel disks. 3DE results correlated and agreed well with those by 3DMRT, with better correlation and agreement than provided by other techniques for LVEDV (3DE: r=.97, SEE=14.7 mL, SD of differences from 3DMRT=14.5 mL; other techniques: r=.84 to .93, SEE=30.7 to 41.6 mL [P<.001 versus 3DE by F test], SD of differences=31.5 to 40.7 mL [P<.001 versus 3DE by F test]). The same also pertained to LVESV (3DE: r=.97, SEE=12.4 mL, SD of differences=12.9 mL; other techniques: r=.81 to .90, SEE=24.7 to 37.2 mL [P<.001], SD of differences=27.6 to 36.8 mL [P<.005]) and LVEF (3DE: r=.74, SEE=5.6%, SD of differences=6.7%; other techniques: r=.14 to .59, SEE=9.5% to 10.1% [P<.01], SD of differences=9.5% to 12.6% [P<.05]). Compared with 3DMRT, 3DE was less time consuming and patient discomfort was less. Tomographic 3DE is an accurate noninvasive technique for calculating LV volumes and systolic function in patients with LV aneurysm. Unlike current 2D methods, tomographic 3DE requires no geometric assumptions that limit accuracy.Keywords
This publication has 23 references indexed in Scilit:
- The use of biplane angiocardiography for the measurement of left ventricular volume in manPublished by Elsevier ,2004
- A new integrated system for three-dimensional echocardiographic reconstruction: Development and validation for ventricular volume with application in human subjectsJournal of the American College of Cardiology, 1993
- Cardiac function by magnetic resonance imagingThe International Journal of Cardiovascular Imaging, 1988
- Quantitative two-dimensional echocardiographic assessment of patients undergoing left ventricular aneurysmectomyAmerican Heart Journal, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Assessment of left ventricular aneurysm resectability by two-dimensional echocardiographyThe American Journal of Cardiology, 1985
- Cross-sectional echocardiography III. Analysis of mathematic models for quantifying volume of symmetric and asymmetric left ventriclesAmerican Heart Journal, 1980
- Biplane apex echocardiography versus biplane cineangiography in the assessment of left ventricular volume and function: Validation by direct measurementsThe American Journal of Cardiology, 1980
- Estimation of left ventricular volumes in man from biplane cineangiograms filmed in oblique projectionsThe American Journal of Cardiology, 1978
- Problems in echocardiographic volume determinations: Echocardiographic-angiographic correlations in the presence or absence of asynergyThe American Journal of Cardiology, 1976