Abstract
Head loss and velocity distribution measurements were made on three annular pipes formed by centrally supporting pipe cores in outer pipes. Knowledge of flow conditions in pipes of this type is important in many engineering applications. The fluid used in the tests was water, and the range of Reynolds numbers tested was from 4,000 to 700,000. A description is given of the apparatus used and the precautions taken to assure conformity to the test conditions.