Experimental analysis of a chemical oxygen-iodine laser
- 15 November 1984
- journal article
- research article
- Published by AIP Publishing in Applied Physics Letters
- Vol. 45 (10) , 1009-1011
- https://doi.org/10.1063/1.95061
Abstract
A small scale chemical oxygen‐iodine laser is described. The maximum extracted cw laser power is 4 W. Water vapor and molecular iodine concentration measurements are presented in addition to the more usual fluorescence measurements. The effects of water vapor on the extracted laser power, on the dissociation of iodine, and on the quenching of the O2 1Δ–I 2P1/2 system, are observed. It is shown that a relatively large amount of water vapor can be tolerated. An interesting practical consequence is the possibility of lasing at the same power level with less dangerous 30% H2O2 instead of the highly concentrated H2O2 used in previous studies.Keywords
This publication has 7 references indexed in Scilit:
- Chain-reaction mechanism for molecular iodine dissociation in the molecular oxygen(1.DELTA.)-iodine atom laserThe Journal of Physical Chemistry, 1983
- Performance characteristics of a transverse-flow, oxygen-iodine chemical laser in a low gas-flow velocityJournal of Applied Physics, 1983
- An efficient, small scale chemical oxygen-iodine laserApplied Physics Letters, 1982
- Chemically pumped iodine laserApplied Physics Letters, 1979
- Efficient operation of a 100-W transverse-flow oxygen-iodine chemical laserApplied Physics Letters, 1979
- Integration over cylindrical luminous volumes using a calibrated piston sourceApplied Optics, 1976
- Absolute Intensities of the Discrete and Continuous Absorption Bands of Oxygen Gas at 1.26 and 1.065 μ and the Radiative Lifetime of the 1Δg State of OxygenThe Journal of Chemical Physics, 1965