Effects of signal‐to‐noise ratio on the accuracy and reproducibility of diffusion tensor imaging–derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T
Top Cited Papers
Open Access
- 29 August 2007
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 26 (3) , 756-767
- https://doi.org/10.1002/jmri.21053
Abstract
Purpose To develop an experimental protocol to calculate the precision and accuracy of fractional anisotropy (FA), mean diffusivity (MD), and the orientation of the principal eigenvector (PEV) as a function of the signal‐to‐noise ratio (SNR) in vivo. Materials and Methods A healthy male volunteer was scanned in three separate scanning sessions, yielding a total of 45 diffusion tensor imaging (DTI) scans. To provide FA, MD, and PEV as a function of SNR, sequential scans from a scan session were grouped into nonintersecting sets. Analysis of the accuracy and precision of the DTI‐derived contrasts was done in both a voxel‐wise and region of interest (ROI)‐based manner. Results An upward bias of FA and no significant bias in MD were present as SNR decreased, confirming results from simulation‐based studies. Notably, while the precision of the PEV became worse at low SNR, no bias in the PEV orientation was observed. Overall, an accurate and precise quantification of FA values in GM requires substantially more SNR than the quantification of white matter (WM) FA values Conclusion This study provides guidance for FA, MD, and PEV quantification and a means to investigate the minimal detectable differences within and across scan sessions as a function of SNR. J. Magn. Reson. Imaging 2007;26:756–767.Keywords
This publication has 43 references indexed in Scilit:
- Regional distribution of measurement error in diffusion tensor imagingPsychiatry Research: Neuroimaging, 2006
- Replicability of diffusion tensor imaging measurements of fractional anisotropy and trace in brainJournal of Magnetic Resonance Imaging, 2003
- Applications of diffusion‐weighted and diffusion tensor MRI to white matter diseases – a reviewNMR in Biomedicine, 2002
- The basis of anisotropic water diffusion in the nervous system – a technical reviewNMR in Biomedicine, 2002
- Fiber tracking: principles and strategies – a technical reviewNMR in Biomedicine, 2002
- From the diffusion coefficient to the diffusion tensorNMR in Biomedicine, 2002
- Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical reviewNMR in Biomedicine, 2002
- Optimised diffusion-weighting for measurement of apparent diffusion coefficient (ADC) in human brainMagnetic Resonance Imaging, 1997
- Absolute Quantitation of Diffusion Constants in Human StrokeStroke, 1997
- Anisotropy of NMR properties of tissuesMagnetic Resonance in Medicine, 1994