Acute thrombosis of a composite ascending aortic conduit containing a bjork‐shiley valve during pregnancy: successful emergency cesarean section and operative repair
- 1 June 1986
- journal article
- case report
- Published by Wiley in Clinical Cardiology
- Vol. 9 (6) , 299-301
- https://doi.org/10.1002/clc.4960090614
Abstract
A 31‐year‐old female had an ascending aortic conduit with a Bjork‐Shiley valve placed for an aortic dissection. A year later she became pregnant and was placed on heparin instead of coumadin therapy. She then developed a distal aortic dissection and was hospitalized for close medical monitoring of fetal status and maturity. At 33 weeks of gestation the aortic valve thrombosed, resulting in pulmonary edema and cardiac arrest. Emergency cesarean section and replacement of the aortic valve and ascending aortic conduit was successful in salvaging mother and child. Both are well at 2 years followup. The case illustrates the hazards of prosthetic valves in pregnant patients and cardiac surgery during pregnancy. These issues are reviewed along with the details leading to successful surgical management.Keywords
This publication has 6 references indexed in Scilit:
- Intracardiac Surgery in Pregnant WomenThe Annals of Thoracic Surgery, 1983
- Pregnancy and Mechanical Valve Prostheses: A High-Risk Situation for the Mother and the FetusThe Annals of Thoracic Surgery, 1983
- Maternal and fetal sequelae of anticoagulation during pregnancyThe American Journal of Medicine, 1980
- Cardiac Valve Prostheses, Anticoagulation, and PregnancyThe Annals of Thoracic Surgery, 1977
- Cardiovascular management of pregnant women with a heart valve prosthesisThe American Journal of Cardiology, 1975
- Congenital malformations associated with the administration of oral anticoagulants during pregnancyThe Journal of Pediatrics, 1975