Transient Myocardial Contrast After Initial Exposure to Diagnostic Ultrasound Pressures With Minute Doses of Intravenously Injected Microbubbles
- 1 November 1995
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 92 (9) , 2391-2395
- https://doi.org/10.1161/01.cir.92.9.2391
Abstract
Background We have observed a transient but significant increase in myocardial contrast intensity with intravenously injected perfluorocarbon-exposed sonicated dextrose albumin (PESDA) microbubbles that occurs on initial exposure to pulsed ultrasound (transient-response imaging). The characteristics and magnitude of this response were examined in the present study. Methods and Results In 14 dogs, the myocardial contrast intensity produced by transient-response imaging (TRI) was compared with conventional 30-Hz imaging (CI) after a 0.005 to 0.030 mL/kg intravenous injection of PESDA. TRI was produced either by measuring myocardial contrast during triggered (1 pulse per cardiac cycle) ultrasound or by withholding real time ultrasound transmission until after microbubbles had entered the myocardium after intravenous injection. Both first-harmonic imaging (2.0 to 3.5 MHz) and second-harmonic imaging (2.0 to 2.5 MHz fundamental, 4.0 to 5.0 MHz received) were used. TRI produced over three times the anterior myocardial contrast intensity of CI (36±12 U TRI versus 11±11 U CI; P <.01), with visually better anterior and posterior myocardial contrast. The spatial extent of myocardial ischemia was easily visualized after intravenous PESDA by use of TRI and correlated closely with risk area as measured with Monastral blue ( r =.99, P =.002). Conclusions TRI produces significantly greater myocardial contrast than CI and may dramatically enhance the ability of intravenous ultrasound contrast agents to identify myocardial perfusion abnormalities.Keywords
This publication has 7 references indexed in Scilit:
- Intravenous perfluoropropane-exposed sonicated dextrose albumin produces myocardial ultrasound contrast that correlates with coronary blood flowJournal of the American Society of Echocardiography, 1995
- Acoustic Lability of Albumin MicrospheresJournal of the American Society of Echocardiography, 1994
- Second harmonic ultrasonic blood perfusion measurementUltrasound in Medicine & Biology, 1993
- Acoustically forced oscillations of air bubbles in water: Experimental resultsThe Journal of the Acoustical Society of America, 1992
- Acoustic cavitation produced by microsecond pulses of ultrasound: A discussion of some selected resultsThe Journal of the Acoustical Society of America, 1992
- Erratum: Transient pulsations of small gas bubbles in water [J. Acoust. Soc. Am. 8 4, 985–998 (1988)]The Journal of the Acoustical Society of America, 1988
- Verification of myocardial contrast two-dimensional echocardiographic assessment of perfusion defects in ischemic myocardiumJournal of the American College of Cardiology, 1984