Evaluation of External-Cavity Diode Lasers for Raman Spectroscopy
- 1 December 1995
- journal article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 49 (12) , 1846-1851
- https://doi.org/10.1366/0003702953965993
Abstract
We have evaluated the suitability of two commercial external-cavity, tunable diode lasers (tuning range approximately 770–800 nm) for use as Raman excitation sources. The tests consisted of relatively long-term (up to 14 h) measurements of wavelength and power stability as well as measurements of reproducibility of emission wavelength during repeated on/off cycling. We find that, for both tested lasers, the external cavity configuration either eliminates or dampens “mode-hopping” and wavelength drift to a level suitable for obtaining good-quality Raman spectra in most routine experiments. Over the course of several hours, wavelength change from both mode-hopping and drift is less than approximately 0.05 nm for the New-Focus laser and 0.07 nm for the SDL laser. Reproducibility over several on/off cycles is of the same order of magnitude. In all cases, resolution measurements were limited by the spectrographs.Keywords
This publication has 43 references indexed in Scilit:
- Near-infrared surface-enhanced Raman spectroscopy of chemisorbed compounds on gold colloidsSurface Science, 1994
- High-Performance Raman Spectroscopic System Based on a Single Spectrograph, CCD, Notch Filters, and a Kr+ Laser Ranging from the Near-IR to Near-UV RegionsApplied Spectroscopy, 1993
- Combined Raman and Fluorescence Spectroscopy with the Same Compact CCD-Based InstrumentApplied Spectroscopy, 1992
- A New Approach to Highly Efficient Raman Spectroscopy Using a Laser Diode and AgGaSe2 Crystal FilterApplied Spectroscopy, 1992
- Fiber-Optic Sampling Combined with an Imaging Spectrograph for Routine Raman SpectroscopyApplied Spectroscopy, 1992
- The Utilization of a Holographic Bragg Diffraction Filter for Rayleigh Line Rejection in Raman SpectroscopyApplied Spectroscopy, 1990
- Near-Infrared Raman Spectroscopy of Liquids and Solids with a Fiber-Optic Sampler, Diode Laser, and CCD DetectorApplied Spectroscopy, 1990
- Evaluation of a diode laser/charge coupled device spectrometer for near-infrared Raman spectroscopyAnalytical Chemistry, 1989
- Near-Infrared Raman Spectroscopy with a 783-nm Diode Laser and CCD Array DetectorApplied Spectroscopy, 1989
- IR Raman spectroscopy with semiconductor devices for excitation and detectionOptics Communications, 1987