Alignment methods for averaging of high-resolution cardiac signals: a comparative study of performance
- 1 June 1991
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 38 (6) , 571-579
- https://doi.org/10.1109/10.81582
Abstract
International audienceAccurate signal estimation by means of coherent averaging techniques needs temporal alignment methods. A known low-pass filtering effect is yielded when alignment errors are present. This is very critical in the estimation of low-level high-frequency potentials in high-resolution ECG analysis. A comparative study of the performance of three alignment methods (the double-level method, a new time-delay estimation method based on normalized integrals, and matched filtering) is presented in this paper. A real signal and additive random noise for several signal-to-noise ratios (SNR's) are selected to make an ensemble of computer-simulated beats. The relation between the standard deviation of temporal misalignment versus SNR is discussed. A second study with real ECG signals is also presented. Several morphologies of QRS and P waves are tested. The results are in agreement with the computer simulation study. Nevertheless, the power spectrum of the noise process can affect the results. Matched filter estimation has been tested in the presence of power line interference (50 Hz), with poor results. An application of the three alignment methods as a function of the SNR is proposed. The new time-delay estimation method has been observed to be robust, even in the presence of nonwhite noiseKeywords
This publication has 13 references indexed in Scilit:
- High resolution ECG analysis by an improved signal averaging method and comparison with a beat-to-beat approachJournal of Biomedical Engineering, 1988
- Coherent averaging technique: A tutorial review Part 2: Trigger jitter, overlapping responses and non-periodic stimulationJournal of Biomedical Engineering, 1986
- Improved Waveform Estimation Procedures for Event-Related PotentialsIEEE Transactions on Biomedical Engineering, 1985
- A Real-Time QRS Detection AlgorithmIEEE Transactions on Biomedical Engineering, 1985
- Estimation accuracy of P wave and QRS complex occurrence times in the ECG: The accuracy for simplified theoretical and computer simulated waveformsSignal Processing, 1984
- Use of signals in the terminal QRS complex to identify patients with ventricular tachycardia after myocardial infarction.Circulation, 1981
- Accuracy of QRS detection in relation to the analysis of high-frequency components in the electrocardiogramMedical & Biological Engineering & Computing, 1979
- Online digital filters for biological signals: some fast designs for a small computerMedical & Biological Engineering & Computing, 1977
- A computerized technique to record new components of the electrocardiogramProceedings of the IEEE, 1977
- Characterization of an adaptive filter for the analysis of variable latency neuroelectric signalsMedical & Biological Engineering & Computing, 1967