Gore-Tex Patch Repair of the Anterior Rectus Sheath in Free Rectus Abdominis Muscle and Myocutaneous Flaps
- 1 June 1996
- journal article
- research article
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 97 (7) , 1436-1440
- https://doi.org/10.1097/00006534-199606000-00019
Abstract
Reconstruction of the breast and other tissues by the free transverse rectus abdominis myocutaneous (TRAM) flap is an accepted, reliable technique with a high success rate. Closure of the anterior rectus sheath defect that results from this flap and the related rectus abdominis muscle-only (RAM) free flap has been the subject of debate, since hernia formation is considered a risk. Some authors prefer direct closure, while others recommend a variety of synthetic mesh reinforcements. We have reviewed 81 patients from a consecutive series of free TRAM and RAM flaps performed by one surgeon (Pennington) over an 8-year period. The majority of patients had repair of the anterior rectus sheath with a 1-mm-thick synthetic patch of polytetrafluoroethylene (Gore-Tex), used in 52 of 71 patients having the TRAM flap and 4 of 10 patients having the RAM flap. There were 5 wound infections (6.2 percent) overall, 3 of which occurred in the Gore-Tex group (5.4 percent). In all 3 of the latter patients, Gore-Tex was removed, although usually only after some months. Even after patch removal, no hernias developed subsequently. The two other infections occurred in patients with a Prolene mesh patch and no patch, respectively. One hernia was found in 71 patients with TRAM flaps, and that was in a patient in whom no patch was used. No hernias occurred in 52 TRAM flap patients with Gore-Tex patches. Hernia formation was noted in 6 of 10 RAM flap patients, although only 1 hernia occurred in the 4 patients with Gore-Tex patches. We conclude that the 1-mm polytetrafluoroethylene (Gore-Tex) patch is a satisfactory method for repair of the anterior rectus sheath after harvesting of either free RAM or TRAM flaps. Even if removal of the patch is required because of infection, the risk of subsequent hernia formation appears minimal. (Plast. Reconstr. Surg. 97: 1436, 1996.)Keywords
This publication has 12 references indexed in Scilit:
- Immediate TRAM Flap Breast ReconstructionPlastic and Reconstructive Surgery, 1993
- THE FREE TRANSVERSE RECTUS ABDOMINIS MYOCUTANEOUS FLAP IN BREAST RECONSTRUCTION AFTER MASTECTOMYAnz Journal of Surgery, 1991
- Abdominal Wall Function after Rectus Abdominis TransferPlastic and Reconstructive Surgery, 1991
- Experience with 50 Free TRAM Flap Breast ReconstructionsPlastic and Reconstructive Surgery, 1991
- Conventional TRAM Flap versus Free Microsurgical TRAM Flap for Immediate Breast ReconstructionPlastic and Reconstructive Surgery, 1989
- Closure of the Donor Defect for Breast Reconstruction with Rectus Abdominis Myocutaneous FlapsPlastic and Reconstructive Surgery, 1985
- Abdominal Wall Competence in Transverse Abdominal Island Flap OperationsAnnals of Plastic Surgery, 1984
- Breast Reconstruction with a Transverse Abdominal Island FlapPlastic and Reconstructive Surgery, 1982
- The rectus abdominis myocutaneous free flapBritish Journal of Plastic Surgery, 1980
- RECTUS ABDOMINIS MYOCUTANEOUS FLAP FOR BREAST RECONSTRUCTIONAnz Journal of Surgery, 1979