Large artery function in patients with chronic heart failure. Studies of brachial artery diameter and hemodynamics.
- 1 December 1991
- journal article
- abstracts
- Published by Wolters Kluwer Health in Circulation
- Vol. 84 (6) , 2418-2425
- https://doi.org/10.1161/01.cir.84.6.2418
Abstract
BACKGROUND: Although progressive chronic congestive heart failure (CHF) is associated with elevated systemic vascular resistance and increased impedance to ventricular outflow, the contribution of changes in large artery function has not been well documented in humans. METHODS AND RESULTS: We studied 45 patients with a broad range of clinical severity of CHF and compared noninvasive measurements of brachial artery diameter, flow, and pulse wave velocity with 22 normal controls of similar age. In CHF, mean arterial pressure was lower than in controls (85 +/- 1 versus 93 +/- 2 mm Hg, p less than 0.001), as were brachial artery diameter (4.07 +/- 0.10 versus 4.53 +/- 0.09 mm, p less than 0.001), flow (40.9 +/- 4.1 versus 70.9 +/- 11.5 ml.min-1, p less than 0.02), compliance (1.29 +/- 0.12 versus 2.00 +/- 0.18 cm4.dyne-1.10(-7), p less than 0.002), and conductance (0.49 +/- 0.05 versus 0.76 +/- 0.13 units, p = 0.06). Limb vascular resistance (40.2 +/- 5.0 versus 20.5 +/- 3.1 units, p less than 0.001) and pulse wave velocity (10.6 +/- 0.5 versus 9.2 +/- 0.4 m.sec-1, p less than 0.03) were higher than in controls. Brachial artery diameter was progressively lower than in controls as severity of CHF increased (New York Heart Association class II, 4.47 +/- 0.23 mm, p = NS; class III, 4.05 +/- 0.10 mm, p less than 0.05; class IV, 3.71 +/- 0.28 mm, p less than 0.05). Similar changes were observed for arterial compliance (class II, 1.76 +/- 0.32 cm4.dyne-1.10(-7), p = NS; class III, 1.21 +/- 0.13 cm4.dyne-1.10(-7), p less than 0.05; class IV, 0.95 +/- 0.10 cm4.dyne-1.10(-7), p less than 0.05). While the lower arterial pressure and flow might be expected to passively reduce arterial diameter, this would be associated with a reduced pulse wave velocity and improved arterial compliance, yet the opposite was observed. Differences in large artery function were not likely caused by underlying atherosclerosis alone, because patients with dilated cardiomyopathy and patients with ischemic heart disease of the same sex, age, left ventricular ejection fraction, and exercise treadmill duration had similar changes in large artery function. CONCLUSIONS: We conclude that alterations in brachial artery function are present in patients with moderate and severe CHF. The observed reduction in arterial compliance, if present diffusely throughout the arterial tree, could increase left ventricular end-systolic stress directly and through increased velocity of reflected pressure waves from the periphery.Keywords
This publication has 25 references indexed in Scilit:
- Arterial vascular compliance response to vasodilators by Fourier and pulse contour analysis.Hypertension, 1988
- Effect of Captopril on Progressive Ventricular Dilatation after Anterior Myocardial InfarctionNew England Journal of Medicine, 1988
- Hemodynamics of the carotid artery after vasodilation in essential hypertension.Hypertension, 1988
- Heterogeneity of Response of Peripheral Arteries to Antihypertensive Drugs in Essential HypertensionDrugs, 1988
- Aortic distensibility abnormalities in coronary artery diseaseThe American Journal of Cardiology, 1987
- Evidence of early degenerative changes in large arteries in human essential hypertension.Hypertension, 1985
- Cardiac hypertrophy and arterial distensibility in essential hypertensionAmerican Heart Journal, 1985
- Simultaneous single isotope radioenzymatic assay of plasma norepinephrine, epinephrine and dopamineLife Sciences, 1977
- Treadmill exercise in assessment of the functional capacity of patients with cardiac diseaseThe American Journal of Cardiology, 1972
- Pulse wave velocity in healthy subjects and in patients with various disease statesAmerican Heart Journal, 1971