Human Umbilical Veins and Autogenous Veins as Canine Arterial Bypass Grafts
- 1 August 1978
- journal article
- research article
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 188 (2) , 158-161
- https://doi.org/10.1097/00000658-197808000-00005
Abstract
Glutaraldehyde treated human umbilical veins (Dardik Biograft) were used to bypass short segments of the femoral artery in 15 dogs and were compared to autogenous jugular veins placed in the contralateral femoral artery of each animal. All 15 autogenous jugular veins remained patent for the four month period of observation whereas thrombosis occurred in seven of 15 umbilical vein grafts. This patency rate of 53% was significantly lower than that observed for autogenous jugular veins (p < 0.01). Neointimal Fibrous Hyperplasia (NFH) at the proximal anastomosis was responsible for six of the seven umbilical vein graft occlusions. Of the eight patent umbilical veins, five had varying degrees of proximal anastomotic stenosis secondary to NFH. Histological examination of each graft revealed significant fibroblastic proliferation and collagen deposition within the lumen of stenosed and thrombosed grafts. Although human umbilical veins have distinct advantages over other prosthetics, such as availability and flexibility, the incidence of experimental neointimal fibrous hyperplasia causing anastomotic stenosis and thrombosis is prohibitively high.This publication has 14 references indexed in Scilit:
- HUMAN UMBILICAL-CORD VEIN FOR VASCULAR REPLACEMENT - PRELIMINARY-REPORT AND OBSERVATIONS1977
- Human umbilical cord. A new source for vascular prosthesisPublished by American Medical Association (AMA) ,1976
- Successful Arterial Substitution with Modified Human Umbilical VeinAnnals of Surgery, 1976
- Evaluation of prosthetic grafts of different porosity for arterial reconstructionThe American Journal of Surgery, 1975
- Modified and unmodified umbilical vein allografts and xenografts as arterial substitutes: morphologic assessment.1975
- Future Directions in the Development of Arterial Prostheses for Small and Medium Caliber ArteriesSurgical Clinics of North America, 1974
- Surface thrombogenicity of arterial prostheses.1973
- The problem of small vessel grafting and the flexion crease: A comparison between autogenous vein and dacron graftsThe American Journal of Surgery, 1963
- Comparison of Peripheral Arterial GraftsArchives of Surgery, 1961
- Study of Elasticized Dacron as Arterial ProsthesisA.M.A. Archives of Surgery, 1959