Fine particle mass (PM2.5), black smoke (BS) and particle number concentration (NC) were measured simultaneously indoors and outdoors at an urban location in Erfurt, Germany. Measurements were conducted during 2-month periods in summer and winter. Different ventilation modes were applied during each measurement period: windows closed; windows opened widely for 15 min twice per day; windows and door across the room opened widely for 5 min twice per day and windows tilted open all day long. The lowest indoor/outdoor (I/O) ratios for all pollutants were found for closed windows, whereas the ratios for ventilated environments were higher. For closed windows, the I/O ratios for PM2.5 are larger than the corresponding values for BS and NC (0.63 vs. 0.44 or 0.33, respectively) probably due to lower penetration factors for particles sizes 2.5 and BS were strongly correlated for all ventilation modes. The linear regression models showed that more than 75% of the daily indoor variation could be explained by the daily outdoor variation for those pollutants. However, the correlation between indoor and outdoor NC for ventilation twice a day was weak. It indicates that rapid changes of the air exchange rates during the day may affect the correlation and regression analysis of NC indoor and outdoor concentrations. This effect was not observed for PM2.5 or BS. This study shows the importance of the indoor air aerosol measurements for health effects studies and the need for more research on I/O transport mechanisms for NC.Keywords
This publication has 30 references indexed in Scilit:
- Activity patterns of Californians: Use of and proximity to indoor pollutant sourcesPublished by Elsevier ,2003
- ‘EUROPART’. Airborne particles in the indoor environment. A European interdisciplinary review of scientific evidence on associations between exposure to particles in buildings and health effectsIndoor Air, 2003
- Comparison between different traffic-related particle indicators: Elemental carbon (EC), PM2.5 mass, and absorbanceJournal of Exposure Science & Environmental Epidemiology, 2003
- Assessment of exposure to traffic related air pollution of children attending schools near motorwaysAtmospheric Environment, 2001
- Exposure assessment of air pollutants: a review on spatial heterogeneity and indoor/outdoor/personal exposure to suspended particulate matter, nitrogen dioxide and ozonePublished by Elsevier ,2000
- Association of fine particulate matter from different sources with daily mortality in six U.S. cities.Environmental Health Perspectives, 2000
- Relative Contribution of Outdoor and Indoor Particle Sources to Indoor ConcentrationsEnvironmental Science & Technology, 2000
- Characterization of indoor particle sources: A study conducted in the metropolitan Boston area.Environmental Health Perspectives, 2000
- A study of characterize indoor particles in three non-smoking homesAtmospheric Environment. Part A. General Topics, 1991
- Indoor Outdoor Aerosol Measurements for Two Residential Buildings in New JerseyAerosol Science and Technology, 1988