Sensitivity distributions of EEG and MEG measurements
- 1 March 1997
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 44 (3) , 196-208
- https://doi.org/10.1109/10.554766
Abstract
It is generally believed that because the skull has low conductivity to electric current but is transparent to magnetic fields, the measurement sensitivity of the magnetoencephalography (MEG) in the brain region should be more concentrated than that of the electroencephalography (EEG). It is also believed that the information recorded by these techniques is very different. If this were indeed the case, it might be possible to justify the cost of MEG instrumentation which is at least 25 times higher than that of EEG instrumentation. The localization of measurement sensitivity using these techniques was evaluated quantitatively in an inhomogeneous spherical head model using a new concept called half-sensitivity volume (HSV). It is shown that the planar gradiometer has a far smaller HSV than the axial gradiometer. However, using the EEG it is possible to achieve even smaller HSV's than with whole-head planar gradiometer MEG devices. The micro-superconducting quantum interference device (SQUID) MEG device does have HSV's comparable to those of the EEG. The sensitivity distribution of planar gradiometers, however, closely resembles that of dipolar EEG leads and, therefore, the MEG and EEG record the electric activity of the brain in a very similar way.Keywords
This publication has 13 references indexed in Scilit:
- BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic FieldsPublished by Oxford University Press (OUP) ,1995
- Correlation between skull thickness asymmetry and scalp potential estimated by a numerical model of the headIEEE Transactions on Biomedical Engineering, 1995
- Images of Conflict: MEG vs. EEGScience, 1991
- Localization of implanted dipoles by magnetoencephalographyNeurology, 1991
- Tests of EEG localization accuracy using implanted sources in the human brainAnnals of Neurology, 1991
- MEG versus EEG localization test using implanted sources in the human brainAnnals of Neurology, 1990
- The influence of model parameters on EEG/MEG single dipole source estimationIEEE Transactions on Biomedical Engineering, 1987
- Corrected Unipositional Lead System for Vector MagnetocardiographyIEEE Transactions on Biomedical Engineering, 1987
- Distribution of m.e.g. detector sensitivity: an application of reciprocityMedical & Biological Engineering & Computing, 1980
- EEG Electrode Sensitivity-An Application of ReciprocityIEEE Transactions on Biomedical Engineering, 1969