Direct potentiometric membrane electrode measurements of heparin binding to macromolecules
- 1 October 1993
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 5 (9-10) , 719-724
- https://doi.org/10.1002/elan.1140050903
Abstract
The use of a newly developed heparin responsive polymeric membrane electrode for directly monitoring the binding of heparin to a variety of other biological macromolecules is examined. Potentiometric titrations of protamine, low‐density lipoprotein (LDL), polybrene, DNase enzyme, and polylysine with either porcine or beef lung heparin can be followed conveniently by the electrode at various solution pHs. Such titrations yield endpoints that are used to determine the stoichiometry for the interaction of the different heparins with these macromolecules. Based on prior heparin calibration curves, the titration data can be recast in Scatchard form to obtain binding constants for these solution‐phase heparin‐macromolecular reactions. The speed and simplicity of the proposed method make it an attractive alternative to classical solid‐phase binding methods or newer homogeneous fluorescent polarization schemes for studying the solution‐phase interaction of heparin with other macromolecules.Keywords
This publication has 20 references indexed in Scilit:
- Heparin binding to human plasma low-density lipoproteins: dependence on heparin sulfation degree and chain lengthBiochemistry, 1992
- Binding studies using ion-selective electrodes. Examination of the picrate-albumin interaction as a model systemAnalytical Chemistry, 1990
- Structure of Heparin and Heparin FragmentsAnnals of the New York Academy of Sciences, 1989
- Effect of trypsin treatment on the heparin- and receptor-binding properties of human plasma low-density lipoproteinsBiochemistry, 1986
- A comparison of the strength of binding of antithrombin III, protamine and poly(l-lysine) to heparin samples of different anicoagulant activitiesBiochimica et Biophysica Acta (BBA) - General Subjects, 1986
- ProtamineAnesthesia & Analgesia, 1985
- Antibody Binding Measurements with Hapten-Selective Membrane ElectrodesScience, 1977
- Membrane electrode measurements of calcium and magnesium ion binding to cyclic AMPBioelectrochemistry and Bioenergetics, 1977
- Acetylcholine-ATP binding by direct membrane electrode measurementBiochemical and Biophysical Research Communications, 1976
- A Comparison of two Heparin-Neutralizing Agents: Protamine and PolybreneScandinavian Journal of Clinical and Laboratory Investigation, 1960