JP-4 FUELED MOLTEN CARBONATE FUEL CELLS

Abstract
Sixteen single molten carbonate fuel cells were assembled and tested. Nine of these were assembled in the alumina tube enclosures and the remaining seven were made in metal flange enclosures. The areas of the alumina tube cells are 3 and 45 sq cm, and the area of the metal flange enclosure cells is 31.7 sq cm. A summary of the conditions used in all 16 tests is given. All tests used 20% dense fiber nickel anodes and paste electrolytes.