Practical considerations in the use of polarized light microscopy in the analysis of the collagen network in articular cartilage
Top Cited Papers
- 10 December 2007
- journal article
- research article
- Published by Wiley in Microscopy Research and Technique
- Vol. 71 (4) , 279-287
- https://doi.org/10.1002/jemt.20551
Abstract
Polarized light microscopy is a traditional method for visualizing the collagen network architecture of articular cartilage. Articular cartilage repair and tissue engineering studies have raised new demands for techniques capable of quantitative characterization of the scar and repair tissues, including properties of the collagen network. Modern polarized light microscopy can be used to measure collagen fibril orientation, parallelism, and birefringence. New commercial instruments are computer controlled and the measurements are easy to perform. However, often the interpretation of results causes difficulties, even errors, because the theoretical aspects of the technique are demanding. The aim of this study was to describe the instrumentation and properties of a modern polarized light microscope, to point out some sources of error in the interpretation of the results, and to recall the theoretical background of the polarized light microscopy. Microsc. Res. Tech., 2008.Keywords
This publication has 16 references indexed in Scilit:
- Imaging the physical and morphological properties of a multi‐zone young articular cartilage at microscopic resolutionJournal of Magnetic Resonance Imaging, 2003
- Spatial assessment of articular cartilage proteoglycans with Gd‐DTPA‐enhanced T1 imagingMagnetic Resonance in Medicine, 2002
- Characteristics of topographical heterogeneity of articular cartilage over the joint surface of a humeral headOsteoarthritis and Cartilage, 2002
- Quantitative in situ correlation between microscopic MRI and polarized light microscopy studies of articular cartilageOsteoarthritis and Cartilage, 2001
- Electron microscopic stereological study of collagen fibrils in bovine articular cartilage: volume and surface densities are best obtained indirectly (from length densities and diameters) using isotropic uniform random samplingJournal of Anatomy, 1999
- Decreased birefringence of the superficial zone collagen network in the canine knee (stifle) articular cartilage after long distance running training, detected by quantitative polarised light microscopy.Annals of the Rheumatic Diseases, 1996
- New polarized light microscope with precision universal compensatorJournal of Microscopy, 1995
- The Nature of LightPublished by Elsevier ,1990
- Birefringence of Articular Cartilage and the Distribution of Collagen Fibril OrientationsConnective Tissue Research, 1983
- The structure and transparency of the corneaThe Journal of Physiology, 1957