Crossed-screw fixation of the unstable thoracic and lumbar spine
- 1 January 1995
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 82 (1) , 11-16
- https://doi.org/10.3171/jns.1995.82.1.0011
Abstract
An ideal spinal construct should immobilize only the unstable spinal segments, and thus only the segments fused. Pedicle fixation techniques have provided operative stabilization with the instrumentation of a minimal number of spinal segments; however, some failures have been observed with pedicle instrumentation. These failures are primarily related to excessive preload forces and limitations caused by the size and orientation of the pedicles. To circumvent these problems, a new technique, the crossed-screw fixation method, was developed and is described in this report. This technique facilitates short-segment spinal fixation and uses a lateral extracavitary approach, which provides generous exposure for spinal decompression and interbody fusion. The technique employs two large transverse vertebral body screws (6.5 to 8.5 mm in diameter) to bear axial loads, and two unilateral pedicle screws (placed on the side of the exposure) to restrict flexion and extension deformation around the transverse screws and to provide three-dimensional deformity correction. The horizontal vertebral body and the pedicle screws are connected to rods and then to each other via rigid crosslinking. The transverse vertebral body screws are unloaded during insertion by placing the construct in a compression mode after the interbody bone graft is placed, thus optimizing the advantage gained by the significant "toe-in" configuration provided and further decreasing the chance for instrumentation failure. The initial results of this technique are reported in a series of 10 consecutively treated patients, in whom correction of the deformity was facilitated. Follow-up examination (average 10.1 months after surgery) demonstrated negligible angulation. Chronic pain was minimal. The crossed-screw fixation technique is biomechanically sound and offers a rapid and safe form of short-segment three-dimensional deformity correction and solid fixation when utilized in conjunction with the lateral extracavitary approach to the unstable thoracic and lumbar spine. This approach also facilitates the secure placement of an interbody bone graft.Keywords
This publication has 10 references indexed in Scilit:
- Short-segment compression instrumentation for selected thoracic and lumbar spine fractures: the short-rod/two-claw techniqueJournal of Neurosurgery, 1993
- Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report.Journal of Bone and Joint Surgery, 1993
- Pedicle Screw Instrumentation for Thoracolumbar Burst Fractures and Fracture-DislocationsSpine, 1992
- Triangulation of Pedicular InstrumentationSpine, 1991
- Biomechanics of Thoracolumbar Spinal FixationSpine, 1991
- Complications with the Variable Spinal Plating SystemSpine, 1989
- Functional Recovery after Decompressive Operation for Thoracic and Lumbar Spine FracturesNeurosurgery, 1986
- Operative Stabilization of the Posttraumatic Thoracic and Lumbar Spine: A Comparative Analysis of the Harrington Distraction Rod and the Modified Weiss SpringNeurosurgery, 1986
- The Effects of Internal Fixation on the Articular Cartilage of Unfused Canine Facet Joint CartilageSpine, 1984
- Lateral extracavitary approach to traumatic lesions of the thoracic and lumbar spineJournal of Neurosurgery, 1976