This report describes the data acquisition electronics for a flow cytometer. The design differs from most instruments in that the signals from a large number of detectors are processed in parallel. Each of the input channels is capable of autonomously measuring and digitizing the fluorescence signals. The digitized values that belong to one particle are collected by digital circuitry and are presented as a compact data package on a special bus. In addition to the pulse values, the data package contains a time marker, information needed for sort decisions, and an error detection code. Specially designed electronic modules that read the information from the bus can take complex multiparameter sort decisions at a very high speed. All events can also be recorded as data lists by a computer. The lists can be used to reconstruct a sort or analysis run. The raw data lists can also be reduced to kinetic curves and/or (gated) multivariate histograms. As a result of the applied scheme of parallel pulse processing, the dead time of the system is independent of the number of parameters measured and the number and time separation of the excitation beams. The instrument has a cycle time of 5 m̈s, which corresponds to a throughput rate of 2 × 105 events/s. At this rate, the incidence of correlation errors is well below 1 in 108 analyzed particles. The system has proved to be reliable and convenient to use in a variety of experiments. Its high speed and low error rate make it well suited for high‐resolution measurements, rare‐event analysis, kinetic measurements, and high‐speed cell sorting.Keywords
This publication has 6 references indexed in Scilit:
- Improved resolution of flow cytometric measurements of hoechst‐ and chromomycin‐A3‐stained human chromosomes after addition of citrate and sulfiteCytometry, 1988
- High‐speed photodamage cell selection using bromodeoxyuridine/Hoechst 33342 photosensitized cell killingCytometry, 1988
- Fluorescence in situ hybridization to interphase cell nuclei in suspension allows flow cytometric analysis of chromosome content and microscopic analysis of nuclear organizationHuman Genetics, 1988
- Anomalous behaviour of forward and perpendicular light scattering of a cyanobacterium owing to intracellular gas vacuolesCytometry, 1987
- Detection of DNA Sequences in Nuclei in Suspension by in Situ Hybridization and Dual Beam Flow CytometryScience, 1985
- Modular electronics for flow cytometry and sorting: The LACEL systemCytometry, 1981