Long-term Angiographic and Clinical Outcome After Percutaneous Transluminal Coronary Angioplasty and Intracoronary Radiation Therapy in Humans

Abstract
Background Ionizing radiation has been shown to reduce neointimal formation after balloon angioplasty in experimental models of restenosis. This study was designed to evaluate the feasibility, safety, and effectiveness of intracoronary radiation therapy (ICRT) after percutaneous transluminal coronary angioplasty (PTCA) for preventing restenosis in human coronary arteries. Methods and Results Twenty-one patients (22 arteries) with unstable angina underwent standard balloon angioplasty. ICRT was performed with the use of an 192Ir source wire that was hand delivered to the angioplasty site. Angiographic follow-up was performed at 24 hours, between 30 and 60 days, and at 6 months. Angioplasty was successful in 19 of 22 lesions, and insertion of the radioactive source wire was successful at all treated sites. Angiographic study at 24 hours demonstrated early late loss of the luminal diameter from 1.92±0.55 to 1.40±0.27 mm. Between 30 and 60 days, repeat angiography demonstrated total occlusion in 2 arteries, a...