Identification of Mislabeled Specimen by Molecular Methods: Case Report and Review
- 1 July 2005
- journal article
- case report
- Published by SAGE Publications in International Journal of Surgical Pathology
- Vol. 13 (3) , 253-258
- https://doi.org/10.1177/106689690501300304
Abstract
Specimen misidentification is a common cause of errors in surgical pathology. We report a case where bone-marrow biopsies from patients of different genders were mislabeled and molecular methods were applied to resolve the identity. A short tandem repeat (STR)-polymerase chain reaction-based assay, commonly used in paternity testing, was employed in an attempt to assign the correct identity to the specimens. However, the specimens had been processed by decalcification and the DNA yield was poor. One of the markers in the assay is the non-STR amelogenin locus that distinguishes the X and Y chromosomes. This amelogenin marker results in a product of low molecular weight, enabling unequivocal resolution of identity despite a poor DNA yield. The prevalence of errors in pathology due to specimen misidentifications is reviewed.Keywords
This publication has 4 references indexed in Scilit:
- Error in Surgical PathologyThe American Journal of Surgical Pathology, 2004
- A Microdissection and Molecular Genotyping Assay to Confirm the Identity of Tissue Floaters in Paraffin-Embedded Tissue BlocksArchives of Pathology & Laboratory Medicine, 2003
- Detection of the Source of Mislabeled Biopsy Tissue Paraffin Block and Histopathological Section on Glass SlideDiagnostic Molecular Pathology, 1998
- Identification of a Mislabeled Fixed Specimen by DNA AnalysisThe American Journal of Surgical Pathology, 1990