Arterial Blood Pressure and Heart Rate Discrepancies Between Handwritten and Computerized Anesthesia Records
- 1 September 2000
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 91 (3) , 612-616
- https://doi.org/10.1097/00000539-200009000-00022
Abstract
Previous publications suggest that handwritten anesthesia records are less accurate when compared with computer-generated records, but these studies were limited by small sample size, unblinded study design, and unpaired statistical comparisons. Eighty-one pairs of handwritten and computer-generated neurosurgical anesthesia records were retrospectively compared by using a matched sample design. Systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and heart rate (HR) data for each 5-min interval were transcribed from handwritten records. In computerized records, the median of up to 20 values was calculated for SAP, DAP, and HR for each consecutive 5-min epoch. The peak, trough, standard deviation, median, and absolute value of the fractional rate of change between adjacent 5-min epochs were calculated for each case. Pairwise comparisons were performed by using Wilcoxon tests. For SAP, DAP, and HR, the handwritten record peak, standard deviation, and fractional rate of change were less than, and the trough and median were larger than, those in corresponding computer records (all with P: < 0.05, except DAP median and HR peak). Considering together all the recorded measurements from all cases, extreme values were recorded more frequently in computerized records than in the handwritten records. The discrepancies between handwritten and computerized anesthesia records suggest that some of the data in handwritten records are inaccurate. The potential for inaccuracy should be considered when handwritten records are used as source material for research, quality assurance, and medicolegal purposes.Keywords
This publication has 7 references indexed in Scilit:
- The Relationship of Cognitive, Personality, and Academic Measures to Anesthesiology Resident Clinical PerformanceAnesthesia & Analgesia, 1999
- The anesthetic record: accuracy and completenessCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1999
- An Algorithm for Assessing Intraoperative Mean Arterial Pressure LabilityAnesthesiology, 1997
- Are automated anesthesia records better?Journal of Clinical Anesthesia, 1992
- Differences Between Handwritten and Automatic Blood Pressure RecordsAnesthesiology, 1989
- Automated charting of physiological variables in anesthesia: A quantitative comparison of automated versus handwritten anesthesia recordsJournal of Clinical Monitoring and Computing, 1988
- Man-made versus computer-generated anesthesia recordsJournal of Surgical Research, 1977