Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion
- 1 January 1997
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 16 (6) , 903-910
- https://doi.org/10.1109/42.650886
Abstract
We present the use of an entropy focus criterion to enable automatic focusing of motion corrupted magnetic resonance images. We demonstrate the principle using illustrative examples from cooperative volunteers. Our technique can determine unknown patient motion or use knowledge of motion from other measures as a starting estimate. The motion estimate is used to compensate the acquired data and is iteratively refined using the image entropy. Entropy focuses the whole image principally by favoring the removal of motion induced ghosts and blurring from otherwise dark regions of the image. Using only the image data, and no special hardware or pulse sequences, we demonstrate correction for arbitrary rigid-body translational motion in the imaging plane and for a single rotation. Extension to three-dimensional (3-D) and more general motion should be possible. The algorithm is able to determine volunteer motion well. The mean absolute deviation between algorithm and navigator-echo-determined motion is comparable to the displacement step size used in the algorithm. Local deviations from the recorded motion or navigator-determined motion are explained and we indicate how enhanced focus criteria may be derived. In all cases we were able to compensate images for patient motion, reducing blurring and ghosting.Keywords
This publication has 21 references indexed in Scilit:
- An evaluation of reconstruction filters for volume renderingPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Algorithms for extracting motion information from navigator echoesMagnetic Resonance in Medicine, 1996
- A new way of averaging with applications to MRIMedical Physics, 1996
- Two-point interference method for suppression of ghost artifacts due to motionJournal of Magnetic Resonance Imaging, 1993
- ISAR motion compensation using the burst derivative measure as a focal quality indicatorInternational Journal of Imaging Systems and Technology, 1992
- Motion artifact correction in MRI using generalized projectionsIEEE Transactions on Medical Imaging, 1991
- Selection of a convolution function for Fourier inversion using gridding (computerised tomography application)IEEE Transactions on Medical Imaging, 1991
- Why MEM does not work in MR image reconstructionMagnetic Resonance in Medicine, 1990
- Comparison of Interpolating Methods for Image ResamplingIEEE Transactions on Medical Imaging, 1983
- Image reconstruction from incomplete and noisy dataNature, 1978