Contact pressures in the human hip joint
- 1 August 1987
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 69-B (4) , 536-541
- https://doi.org/10.1302/0301-620x.69b4.3611154
Abstract
The pressure distribution between the cartilaginous surfaces in the human hip joint was measured using pressure-sensitive film. Five cadaveric hip joints (aged between 58 and 87 years) were measured at three positions and loads, representing three instants in the stance phase of the walking cycle. The pressure distribution was not uniform, indicating that the cartilage did not, to any great extent, distribute the applied load. The maximum pressures recorded were about 10 MN/m2. The anterosuperior surface of the cartilage was identified as an area of high pressure.This publication has 4 references indexed in Scilit:
- Direct measurement of local pressures in the cadaveric human hip joint during simulated level walking.Annals of the Rheumatic Diseases, 1985
- Synovial fluid circulation in the hip jointMedical Hypotheses, 1984
- The incongruous hip joint: a loading study.Annals of the Rheumatic Diseases, 1984
- Influence of Cartilage Geometry on the Pressure Distribution in the Human Hip JointScience, 1979