A three-dimensional finite element model of human transthoracic defibrillation: paddle placement and size
- 1 June 1995
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 42 (6) , 572-578
- https://doi.org/10.1109/10.387196
Abstract
A detailed 3-D finite element model of the conductive anatomy of the human thorax has been constructed to quantitatively assess the current density distribution produced in the heart and thorax during transthoracic defibrillation. The model is based on a series of cross-sectional CT scans and incorporates isotropic conductivities for eight tissues and an approximation of the anisotropic conductivity of skeletal muscle. Current density distributions were determined and compared for four paddle pairs and two paddle sizes. The authors' results show that the myocardial current density distributions resulting from a defibrillation shock were fairly uniform for the paddle pairs and sizes examined in this study. Specific details of the spatial distribution of the current density magnitudes in the heart were found to depend on paddle placement and size. When the minimum current necessary to defibrillate was delivered, the maximum myocardial current density produced with any of the paddle sizes and positions examined was less than four times the minimum current density necessary to render a myocyte in a fibrillating heart inexcitable, and less than 40% of the damage threshold. These results suggest that common clinically used defibrillation paddle positions have a safety margin as large as 2.5 for current and /spl sim/6 for energy.<>Keywords
This publication has 31 references indexed in Scilit:
- Finite element models of thoracic conductive anatomy: sensitivity to changes in inhomogeneity and anisotropyIEEE Transactions on Biomedical Engineering, 1994
- Current Concepts for Selecting the Location, Size and Shape of Defibrillation ElectrodesPacing and Clinical Electrophysiology, 1991
- Electrode pad size, transthoracic impedance and success of external ventricular defibrillationThe American Journal of Cardiology, 1989
- Three-dimensional computer model of electric fields in internal defibrillationProceedings of the IEEE, 1988
- Transthoracic resistance in human defibrillation. Influence of body weight, chest size, serial shocks, paddle size and paddle contact pressure.Circulation, 1981
- Therapeutic indices for transchest defibrillator shocks: Effective, damaging, and lethal electrical dosesAmerican Heart Journal, 1980
- Cardiac damage produced by direct current countershock applied to the heartThe American Journal of Cardiology, 1979
- Effectiveness of direct current defibrillation: Role of paddle electrode sizeAmerican Heart Journal, 1977
- Termination of ventricular fibrillation in dogs by depolarizing a critical amount of myocardiumThe American Journal of Cardiology, 1975
- Myocardial Necrosis from Direct Current CountershockCirculation, 1974