Cochlear reimplantation
- 1 March 1999
- journal article
- research article
- Published by Wiley in The Laryngoscope
- Vol. 109 (3) , 351-355
- https://doi.org/10.1097/00005537-199903000-00002
Abstract
Objective: A small number of multichannel cochlear implant (CI) recipients require reimplantation. This study describes the causes of failure, surgical technique, and hearing outcomes in a consecutive series of 16 patients undergoing reimplantation of multichannel devices. We hypothesize that reimplantation is safe and that hearing results are at least as good as those measured following primary implantation. Study Design: Retrospective analysis of consecutive clinical series. Methods: Chart analysis of 191 consecutive CI operations performed at the University of Miami Ear Institute between 1990 and 1997 revealed 16 patients who received a second multichannel device. All but one had a minimum follow-up of 1 year after reimplantation. Ten of these patients had initial implantation performed by us, and six were initially operated on elsewhere. Main outcomes of the initial procedure were compared with those of the reimplantation, including electrode insertion length, number of channels programmed, and audiometric results. In addition, cause of failure and relevant surgical findings at the second procedure are described. Results: There were no surgical complications after reimplantation surgery. Device failure was the most frequent cause for reimplantation. Time between initial implantation and failure ranged from 0 to 46 months (mean, 22.4 mo; median, 23 mo). Common intraoperative findings include mastoid fibrosis, bone growth at the cochleostomy, and skin flap breakdown. Following reimplantation, mean length of insertion, number of channels actively programmed, and speech recognition scores were at least as good as findings before initial implant failure. Conclusion: CI reimplantation is safe and effective.Keywords
This publication has 12 references indexed in Scilit:
- Explanatation of a nucleus multichannel cochlear implant and re-implantation into the contralateral ear. A case report of a new strategyThe Journal of Laryngology & Otology, 1996
- How I do it: Otology and neurotology: Fixation of the electrode cable during cochlear implantation: The split bridge techniqueThe Laryngoscope, 1995
- Considerations of cochlear implant surgeryClinical Otolaryngology, 1993
- Speech changes following reimplantation from a single-channel to a multichannel cochlear implantThe Journal of the Acoustical Society of America, 1992
- Auditory Perception Changes After Reimplantation in a Child Cochlear Implant UserEar & Hearing, 1992
- Cochlear Implants: Histopathologic Findings Related to Performance in 16 Human Temporal BonesAnnals of Otology, Rhinology & Laryngology, 1991
- Results of cochlear implant reinsertionThe Laryngoscope, 1991
- Cochlear Implant Revision: Effects of Reimplantation on the CochleaAnnals of Otology, Rhinology & Laryngology, 1989
- Medical or Surgical Complications Related to the Nucleus Multichannel Cochlear ImplantAnnals of Otology, Rhinology & Laryngology, 1988
- Histopathology of an Ear after 5 Years of Electrical StimulationAnnals of Otology, Rhinology & Laryngology, 1986